Gira 5423 00 Operating Instructions Manual Download Page 2

Figure 2: Radio actuator/push-button actuator potential-free

(1) Operating mode switch
(2) Button 

Prog

(3) Status LED
(4) Measuring points for voltage measurement, terminals rear-mounted

3 Function

Intended use

-

Switching of lighting

-

Operation with suitable eNet radio transmitters

-

Installation in appliance box according to DIN 49073

-

Installation in surface-mounted housing or panel-mounted housing (accessories) for
suspended ceilings

Product characteristics

-

Operating mode switch for switch/push-button actuator switch-over or parameterisation via
eNet server

-

Status feedback to radio transmitter

-

Scene operation possible

-

Switchable output with 

Prog

 button

-

Status indicator via LED

Switching mode of operation:
-

Switch-on telegram: Device switches on

-

Switch-off telegram: Device switches off

Operating mode buttons:
-

Relay contact remains closed as long as ON or OFF telegrams are being received

-

The maximum switch-on time is 60 seconds

Can be set with eNet server:
-

Flash function

-

Run-on time

-

Switch-on delay / switch-off delay

-

Operation as NO or NC contacts

-

Switch-off warning

-

Minimum switching repeat time

-

Operation locks

-

Continuous on, Continuous off

i

If settings are changed with the eNet server, operation and signalling could vary from what
is described here.

32581212

10499450

09.05.2016

2/11

eNet

Wireless switching/momentary-contact actuator, 1-gang Mini, Wireless
switching/momentary-contact actuator, 1-gang Mini, zero-voltage

Summary of Contents for 5423 00

Page 1: ...gerous voltage to the device or load Danger of electric shock Device is not suitable for disconnection from supply voltage Danger of electric shock on the SELV PELV installation Not suitable for switc...

Page 2: ...sible Switchable output with Prog button Status indicator via LED Switching mode of operation Switch on telegram Device switches on Switch off telegram Device switches off Operating mode buttons Relay...

Page 3: ...trical connection DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before carrying out work on the device or load disengage all the corresponding circuit breakers Cov...

Page 4: ...ion Function PC Operating mode and parameter set with eNet server M Operating mode buttons K Switching mode of operation If the operating mode switch is turned from the position PC to another operatin...

Page 5: ...actuator or radio transmitter are occupied i All On and All Off buttons of a radio transmitter are connected to the actuator automatically as soon as the first connection to the radio transmitter tak...

Page 6: ...onnection single stranded 0 75 4 mm Finely stranded with conductor sleeve 0 75 2 5 mm Dimensions H 53 28 mm Radio frequency 868 0 868 6 MHz Transmission capacity max 20 mW Transmitting range in free f...

Page 7: ...essed Flashing Switch on starts flashing and switch off stops flashing The default flash frequency is 1 Hz This frequency is also the maximum flash frequency The flash frequency can be changed using p...

Page 8: ...ot yet been switched off due to the delay when a switch on command comes then the load will remain on In Flashing operating mode the pulse times are set using this parameter Comment The set times appl...

Page 9: ...ing the switch off warning a switch on telegram effects direct switch on It is not possible to terminate the time using a switch off telegram Priority lock out protection 0 4 Basic setting 1 Specifies...

Page 10: ...on Minimum switching repeat time 100 ms 10 sec Basic setting 100 ms Limits the switching speed of the device by increasing the value in order to protect the load for example Only when the set time has...

Page 11: ...ira de konformitaet 6 5 Warranty The warranty follows about the specialty store in between the legal framework as provided for by law Please submit or send faulty devices postage paid together with an...

Reviews: