MAINTENANCE
980146 02/07/04
4-6
PERIODIC MAINTENANCE
Twice a month, flush a white vinegar solution (one
quart vinegar to two gallons of water) or anti-
browning solution (mixed as directed) through the
machine. This will prevent build-up of alkaline
residue in the system. If spray jets become clogged,
remove the spray tips, wash them thoroughly, and
blow dry.
NOTE: Do not use pins, wires, etc. to clean nozzles
as this could destroy the spray pattern.
Periodically inspect all hoses, electrical cables and
connections on your machine. Frayed or cracked
hoses should be repaired or replaced to eliminate
vacuum or solution pressure loss. The electrical
cable must be well insulated and cable connector
screw kept tight. If the cable insulation is broken or
frayed, repair or replace immediately. Don’t take
chances with elctrical fire or shock.
DAILY/REGULAR MAINTENANCE
Before making any adjustments to the machine,
disconnect the power cord from the electrical source.
1.
Empty unused cleaning solution from the
solution tank.
2.
Inspect and clean filter screen in solution tank.
3.
Flush pumping system with 4 to 7 liters of clean
water.
4.
After each use, rinse tank with fresh water.
Periodically inspect the recovery tank and
decontaminate if necessary, using a Hospital Grade
Virucide or a 10-1 bleach to water solution. Waste
water should be disposed of properly.
5.
Remove filter to clean. Filters used for wet pick-
up including striper must be thoroughly cleaned
before being allowed to dry.
6.
Check spray jets for full spray pattern.
NOTE: Worn filters can affect vacuum
performance. Replace the filter when it becomes
worn out and normal cleaning will not restore
vac performance.
SERVICE SCHEDULE
DAILY
WEEKLY
QUARTERLY
Check machine for cord damage
*
Check recovery dome and gasket for damage and
cleanliness
*
Check hoses for wear, blockages, or damage
*
Check handles, switches, and knobs for damage
*
Check vac motor intake filter and clean
*
Run one gallon of water through system
*
Clean out recovery tank and check float valve to make
sure it moves freely
*
Clean out solution tank and remove and clean vacuum
intake screen
*
Clean outside of all tanks and check for damage
*
Run vac motor for at least one minute to allow motor to
dry
*
Store with dome off tank to allow the tank to dry
*
Check all bearings for noise
*
Check all gaskets for wear and leakage
*
Check vacuum intake screen for damage; replace if
necessary
*
Check pump pressure; observe spray pattern and
check with gauge if necessary
*
Check and clean solution screen
*
Check cables for fraying
*
Check overall performance of machine
*
Check vac motor carbon brushes
*
Summary of Contents for Century 400
Page 24: ...BASE 980146 03 31 04 5 1 1 3 2 1 2 3 8 3 1 7 6 5 4 2 13 3 11 10 9 3 12 1 3 14 15 3 2 3 2 ...
Page 26: ...CONTROLS 980146 12 04 04 5 3 23 4 1 2 3 17 16 15 14 12 11 10 5 6 7 7 13 18 8 9 19 21 22 20 ...
Page 28: ...LABELS STRAPS 980146 02 07 04 5 5 1 2 3 ...
Page 30: ...RECOVERY TANK 980146 02 07 04 5 7 10 1 15 14 13 12 11 8 9 2 4 5 6 3 7 3 ...
Page 32: ...SOLUTION HOSES FITTINGS 980146 11 05 04 5 9 ...
Page 34: ...SOLUTION PUMP MOTOR 980146 03 31 04 5 11 ...
Page 36: ...SOLUTION PRIME PUMP 980146 03 31 04 5 13 ...
Page 40: ...VACUUM MOTOR 980146 03 31 04 5 17 2 6 1 3 4 5 7 8 9 10 ...
Page 42: ...TOOLS STANDARD 980146 02 07 04 5 19 ...
Page 46: ...TOOLS LOW FLOW SPRAY GUN OPTION 980146 02 07 04 5 23 5 4 3 1 2 6 ...
Page 48: ...TOOLS GROUT CLEANER OPTION 980146 02 07 04 5 25 ...
Page 50: ...TOOLS HIGH PRESSURE WAND OPTION 980146 02 07 04 5 27 ...
Page 52: ...TOOLS CARPET TOOL OPTION 980146 02 07 04 5 29 ...