980146  11/05/04 

5-9 

 

Summary of Contents for Century 400

Page 1: ...Operating Instructions SPECIALTY SURFACE CLEANING MACHINE 980146 12 02 05 J Read these instructions before using the machine MODELS GU10 ...

Page 2: ...e recovery tank YOUR DEALER Name ____________________________________________________________________________ Address __________________________________________________________________________ Phone Number ____________________________________________________________________ MODEL _______________________________________ DATE OF PURCHASE __________________________ SERIAL NUMBER _____________________...

Page 3: ... Off 4 2 Strainer 4 2 Circuit Breakers 4 2 Vacuum Motor Replacement 4 3 Vacuum Motor Brush Replacement 4 3 Solution Pump Replacement 4 4 Regulating Unloader 4 5 Periodic Daily Maintenance 4 6 Service Schedule 4 6 Machine Troubleshooting 4 7 GROUP PARTS LIST Base 5 1 Controls 5 3 Labels Straps 5 5 Recovery Tank 5 7 Solution Hoses Fittings 5 9 Solution Pump Motor 5 11 Solution Prime Pump 5 13 Soluti...

Page 4: ...ution Pump Daily Maintenance Periodic Maintenance Service Schedule Machine Troubleshooting The PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of information REF column refers to the reference number on the parts illustration PART NO column lists the part number for the part QTY column lists the quantity of the part...

Page 5: ...rized service center Do not pull or carry machine by electrical cord use as a handle close a door on cord or pull cord around sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces Do not unplug machine by pulling on cord To unplug grasp the electrical plug not the electrical cord Do not handle the electrical plug or machine with wet hands Do not operate the machin...

Page 6: ...e operation of equipment Report machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentially dangerous conditions to the operator or the equipment Read this information carefully Know when these conditions can exist Locate all safety devices on the machine Please take the necessary steps to t...

Page 7: ...y grounded outlet is not available The temporary adaptor should be used only until a properly grounded outlet Fig A can be installed by a qualified electrician The green colored rigid ear lug or wire extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adaptor is used it must be held in place by a metal screw Improper connecti...

Page 8: ...on the machine If at any time the labels become illegible contact your C400 representative for prompt replacement WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK USE INDOORS ONLY AND ALWAYS INSTALL FLOAT BEFORE ANY WET PICK UP OPERATION USE ONLY DETERGENT INTENDED FOR CLEANING CARPETS WARNING LABEL 500009 ...

Page 9: ...he sound pressure level at 1m from the machine was measured to be 76 dBA This was a nearfield broadband measurement taken in a typical industrial environment on a tile floor This appliance contains no possible source of impact noise The instantaneous sound pressure is below 63 Pa The weighted root mean square acceleration at the operator s arms was measured to be below 2 5m s2 This was a tri axial...

Page 10: ...rty solution off the floor The vacuum motor provides suction to draw the dirty solution off the floor and into the recovery tank The float shut off protects the vacuum fan from over filling The recovery tank stores the dirty solution The function of the chemical system is to dispense chemical into the clean water system The chemical system consists of the chemical reservoir chemical cap and a chem...

Page 11: ...ANK LID RECOVERY TANK RECOVERY TANK LID VACUUM ACCESSORY TOOL HOOK UP SOLUTION ACCESSORY TOOL HOOK UP RECOVERY TANK DRAIN VALVE BASE ASSEMBLY SOLUTION TANK FILL HOSE CASTER LOCK HOSE STORAGE CHEMICAL SIPHON CAPS ELECTRICAL CORD AUTO SOLUTION FILL CONNECTION ...

Page 12: ...OLS 980146 12 04 04 3 4 1 Vacuum Switch 2 Vacuum Circuit Breaker 3 Pump Circuit Breaker 4 Pump Switch 5 Prime Pump Switch 6 Chemical Selector and Metering Valve 7 Solution Auto Fill Connection 1 2 3 4 5 7 6 ...

Page 13: ...lution pump if necessary 6 CHEMICAL SELECTOR AND METERING VALVE Meters the amount of chemical being dispensed and selects between chemical A or chemical B and OFF 7 SOLUTION AUTO FILL CONNECTION The valve and float inside the tank automatically turn the water flow on and off to keep the tank full Use only with normal city water pressure Connect hose to wall faucet Remove cap from machine hose conn...

Page 14: ...o solution tank Use COLD WATER Add 1 oz of GinsuRinse to each full solution tank 3 If needed prime pump by sealing gun to vacuum port and spraying directly at low pressure 4 Attach the adapter cap and intake hose to the Chemical bottle Refer to the Chemical Label for the desired dilution 5 Position the machine in the door way lock front casters Start at furthest point in the room and work towards ...

Page 15: ...ing surfaces at high pressure 9 Use Squeegee or Gulper tool to remove standing water 10 Store and secure hoses and tools neatly 11 Drain machine at proper disposal areas Use pressure gun to rinse and clean recovery tank 12 When using dry filter gently remove and wash with water after every use Allow to dry before re using ...

Page 16: ...compatible materials are not of the type used for carpet cleaning Only use chemicals approved for use with this machine Use of non compatible chemicals may cause machine damage and will not be covered under the warranty Carefully read ingredients on manfacturer s label before using any product in this machine Do not let pump run dry Do not let pump run unattended CHEMICALS Suitable Chemicals Alkal...

Page 17: ...MAINTENANCE 980146 02 07 04 4 1 1 Float Shut Off 2 Strainer 3 Circuit Breakers 4 Vacuum Motor 5 Pump 6 Adjustable Unloader Valve 1 2 3 5 6 4 ...

Page 18: ... check the stainer for debris Drain the solution tank and clean the solution strainer To remove the strainer turn the bottom part of the strainer counterclockwise until the bottom is separated Clean out the debris from the wire mesh and reassemble Make sure the o ring gasket is in place when reassembled 3 CIRCUIT BREAKERS Circuit breakers interrupt the flow of power in the event of an electrical o...

Page 19: ... length shortens due to increased heat Spring inside brush housing will damage motor if brushes are allowed to wear away completely Periodically check the length of the carbon brushes Replace both carbon brushes when either is less than 3 8 9 5mm long 3 8 9 5mm Important These brushes wear quicker as the length shortens due to increased heat Spring inside brush housing will damage motor if brushes...

Page 20: ...itches and unplug machine 2 Drain tanks and remove all chemicals and accessories 3 Unlatch two front latches and hinge tanks back 4 Remove the solution hoses from the fittings on the pump 5 Remove the clamp that fastens the pump to the motor 6 Reverse process to install TORQUE CHART ITEM SIZE IN LBS Nm PUMP INLET 1 2 25 3 CLAMP SCREW 10 32 20 2 4 PUMP SEAL KIT 47434 PUMP VALVE KIT 47435 ...

Page 21: ... all switches and unplug machine 2 Drain tanks and remove all chemicals and accessories 3 Unhook front latches and tilt tanks back so inside of base frame is exposed 4 Remove the solution hoses from the fittings on the pump 5 Remove the unloader 6 Reverse process to install NOTE Kit 47436 includes all o rings marked with an asterisk below INLET BYPASS OUTLET ...

Page 22: ...covery tank and decontaminate if necessary using a Hospital Grade Virucide or a 10 1 bleach to water solution Waste water should be disposed of properly 5 Remove filter to clean Filters used for wet pick up including striper must be thoroughly cleaned before being allowed to dry 6 Check spray jets for full spray pattern NOTE Worn filters can affect vacuum performance Replace the filter when it bec...

Page 23: ...Vac motor hose or dome gasket Replace Pump inlet screen plugged Clean inlet screen Pump circuit breaker tripped Reset breaker Faulty pump switch Call for service Faulty pump motor Call for service Pump air locked Press trigger to open valve on cleaning wand to relieve air Pump runs no solution Internal or external solution line damaged and leaking Replace Jet orifice on cleaning wand is to large T...

Page 24: ...BASE 980146 03 31 04 5 1 1 3 2 1 2 3 8 3 1 7 6 5 4 2 13 3 11 10 9 3 12 1 3 14 15 3 2 3 2 ...

Page 25: ...SS 4 87095 4 WASHER 10 FLAT PLTD 5 140 05 2 DRAW PULL LATCH STD 6 280 02 4 RIVET AL 3 16 X 1 2 CLOSED 7 18044 2 CASTER 4 SWIVEL W BRAKE 8 87080 2 WASHER 5 X 1 25 FLAT GR8 PLT 9 57196 2 NUT 1 2 PUSH ON DOME CAP 10 040 06 2 WHEEL 8 BLK CENTERED HUB 11 56 502068 1 AXLE ASSEMBLY 12 75443 1 BASE 13 46 802536 1 HINGE SOL VAC TANK 4 X 8 14 140668 1 BRKT TOOL BASE 15 75444 1 TRAY 15 X 2 X 4 ...

Page 26: ...CONTROLS 980146 12 04 04 5 3 23 4 1 2 3 17 16 15 14 12 11 10 5 6 7 7 13 18 8 9 19 21 22 20 ...

Page 27: ...SHER 10 X 9 16OD 9 57090 8 NUT 10 32 HEX NYLOCK SS 10 14942 2 BOOT 3 8 CIRCUIT BREAKER 11 72128 1 SWITCH DPDT 2 POSITION ROCKER 12 500813 1 LABEL SWITCH PANEL 13 620014 1 PLATE SWITCH PANEL 14 14832 1 BREAKER 6A VDE CIRCUIT 15 14635 1 BREAKER 10A CIRCUIT 16 390 09A 1 WASHER 9 16 S S USS THICK 17 22015 1 COUPLER 1 4 QD 18 500812 1 LABEL CHEM PANEL 19 72126 1 SWITCH DPDT 3 POSITION ROCKER 20 27051 2...

Page 28: ...LABELS STRAPS 980146 02 07 04 5 5 1 2 3 ...

Page 29: ...LABELS STRAPS 980146 03 31 04 5 6 REF PART NO QTY DESCRIPTION SERIAL NO FROM NOTES 1 500794 1 LABEL C400 LOGO 2 500811 2 LABEL MAIN GINSU 3 320 05 1 STRAP VELCRO ...

Page 30: ...RECOVERY TANK 980146 02 07 04 5 7 10 1 15 14 13 12 11 8 9 2 4 5 6 3 7 3 ...

Page 31: ...69 1 BRKT HOSE 5 260 33 1 HOSEBARB 1 5 MPT X 1 5 6 140 05 2 DRAW PULL LATCH STD 7 15 808123 1 DUMP VALVE 2 8 11 800444 1 ELBOW 2 45D PVC SCH40 9 70683 4 SCR 10 32 X 3 8 PPHMS SS NP 10 31002 1 ELBOW 1 5 FPT X FS PVC 11 81491 4 SET SCR 5 16 18 X 1 5 CP SS 12 75445 1 TANK RECOVERY 13 35255 1 GASKET TANK LID 14 260 64A 1 ACCESS COVER CLEAR 6 W RIM 15 70546 6 SCR 8 X 3 4 PFHT S BLK ZINC ...

Page 32: ...SOLUTION HOSES FITTINGS 980146 11 05 04 5 9 ...

Page 33: ... WIRE BOUND X 3 5 39631 1 HOSE 1 2 WIRE BOUND X 25 6 27051 4 CABLE TIE 11 38 UL CSA 7 40039 2 HOSEBARB 1 2 MPT X 1 2 HOSE 90 8 730262 1 STRAINER 1 2 FPT 80 MESH 73785 SCREEN 80 MESH SERVICE ONLY 27372 CAP STRAINER 26 32 SERVICE ONLY 59021 O RING FILTER SEAL RON VIK SERVICE ONLY 9 830147 1 HOSEBARB 1 2 X 1 2 X 3 8 TEE 10 78561 1 TEE CHEMICAL SIPHON 11 84188 1 VALVE CHECK 1 2 HOSEBARB 12 39634 1 HOS...

Page 34: ...SOLUTION PUMP MOTOR 980146 03 31 04 5 11 ...

Page 35: ...T X 1 4 FPT 6 84190 1 VALVE REGULATING UNLOADER 7 65230 1 PUMP 500 PSI 1GPM 8 70015 4 SCR 1 4 20 X 3 4 HHCS SS NP 9 53265 1 MOTOR 115V 1 3HP PUMP 10 87013 4 WASHER 1 4 ID C 5 8 OD SS 11 57123 4 NUT 1 4 20 CAPTIVE 074 W 12 20105 1 CLAMP PUMP TO MOUNT SERVICE ONLY 13 40068 1 HOSEBARB 3 8 NPT X 1 2 TEE DL 14 730259 1 SPACER 88 OD X 719 ID X 385 L 15 830147 1 HOSEBARB 1 2 X 1 2 X 3 8 TEE 16 39361 1 HO...

Page 36: ...SOLUTION PRIME PUMP 980146 03 31 04 5 13 ...

Page 37: ...HOSE D SLOT 2 40066 2 HOSEBARB 1 8 NPT X 3 8 90 PLAST 3 57245 2 NUT 1 4 20 HEX NYLOCK SS 4 140446 2 BRKT PVC FLOJET PUMP L SHAPE 5 87013 4 WASHER 1 4 ID X 5 8 OD SS 6 70015 2 SCR 1 4 20 X 3 4 HHCS SS NP 7 250 78 1 PUMP 110 120 60HZ FLOJET 8 87016 1 WASHER 10 LOCK EXT STAR SS 9 70323 1 SCR 10 32 X 1 4 PHTR PLTD ...

Page 38: ...SOLUTION TANK 980146 03 31 04 5 15 17 7 16 10 8 22 21 23 1 4 3 4 5 6 2 3 9 15 14 13 12 11 20 18 19 25 24 ...

Page 39: ...6 18 HEX NYLOCK SS 10 87222 4 WASHER SEAL 5 16 X 3 4 OD 11 40077 1 HOSEBARB 3 4MPT X 1 2 HOSE 12 39633 1 HOSE ASM SOLUTION FILL 13 66405 1 PIN BOTTLE LOCK 14 730232 2 STRAP 1 5 X 8 00 VELCRO 15 70683 4 SCR 10 32 X 3 8 PPHMS SS NP 16 140667 1 BRKT TOOL HOLDER 17 56 502072 1 LID SOLUTION TANK 18 41386 1 HOOK SAFETY CLIP 19 34419 1 FITTING PLUG GARDEN HOSE 20 34420 1 FITTING GARDEN HOSE F X 1 2FPT 21...

Page 40: ...VACUUM MOTOR 980146 03 31 04 5 17 2 6 1 3 4 5 7 8 9 10 ...

Page 41: ... 5 SS 4 87013 3 WASHER 1 4ID X 5 8OD SS 5 57105 3 NUT 1 4 20 HEX W STAR WASHER 6 360 04A 1 VAC MOTOR 120V 5 7 2 ST TD 360 04B BRUSHES VACUUM FOR 116392 00 SERVICE ONLY 140687 BRUSH SET 120V VAC WINDSOR 1000121568 SERVICE ONLY 7 20092 1 CLAMP 3 5 WORM GEAR 8 39697 1 HOSE 3 15 ID X 7 0L VENT 9 87016 1 WASHER 10 LOCK EXT STAR 10 70191 1 SCR 10 24 X 1 2 HHTC TYPE 23 ...

Page 42: ...TOOLS STANDARD 980146 02 07 04 5 19 ...

Page 43: ...DLE 3 02475 1 TOOL GULPER 4 02479 1 TOOL TILE BRUSH 5 02480 1 TOOL ALUMINUM WAND 6 02473 1 TOOL WHEELED SQUEEGEE 7 02481 1 TOOL DOOR WEDGE 8 36233 1 GUN PRESSURE WASH 9 56014 1 NIPPLE 1 4 CLOSE 10 58005 1 NOZZLE ADJUSTABLE HI LO 11 56012 1 NIPPLE 1 4 FPT QD 12 39578 1 HOSE ASM 1 4HP SLTN 25 FT NOT SHOWN 13 39637 1 HOSE ASM 1 5 X 30 FT NOT SHOWN ...

Page 44: ... WHT BLK BLK 2 880420 880420 WHT BLK 9 8 2 GRN YLW GRN 6 2 7 2 5 4 WHT BLK BLK WHT PANEL GROUND PANEL GROUND 41492 PRIMING PUMP WHT GRN YLW BLK BLK WHT GRN YLW GRN YLW WHT BLK PUMP MOTOR VACUUM MOTOR POWER VACUUM CIRCUIT BREAKER 10 AMP VACUUM SWITCH PUMP CIRCUIT BREAKER 6 AMP PUMP SWITCH ...

Page 45: ...23716 1 CORD SET 14 3 X 31 4 23215 1 CORD SET 14 3 X 50 GFCI YLW NOT SHOWN SUGGESTED SPARE PARTS PART NO DESCRIPTION SERIAL NO FROM NOTES 47419 KIT SQUEEGEE TOOL BLADES 730262 STRAINER 1 2 FPT 80 MESH 360 04B BRUSHES VAC FOR 116392 00 140687 BRUSH SET 120V VAC WINDSOR 1000121568 53266 VAC MOTOR ASM 115V W TERM 14942 BOOT 3 8 CIRCUIT BREAKER 14832 BREAKER 6A VDE CIRCUIT 14635 BREAKER 10A CIRCUIT ...

Page 46: ...TOOLS LOW FLOW SPRAY GUN OPTION 980146 02 07 04 5 23 5 4 3 1 2 6 ...

Page 47: ...F PART NO QTY DESCRIPTION SERIAL NO FROM NOTES 1 84186 1 VALVE FLOW ADJUSTMENT 84186 2 36233 1 GUN PRESSURE WASH 36233 3 56012 1 NIPPLE 1 4 FPT QD 56012 4 51389 1 LANCE SPRAY GUN 51389 5 44078 1 JET 1 H VV 8003 44078 6 47427 REF KIT LOW FLOW SPRAY GUN 47427 ...

Page 48: ...TOOLS GROUT CLEANER OPTION 980146 02 07 04 5 25 ...

Page 49: ...OSE 3 11 800133 1 TEE 1 8 BR 4 39639 2 HOSE 1 8 MPT X 1 4 FPT X 8L 5 87015 4 WASHER 9 16 ID X 1 06 OD SS 6 44079 2 JET 1 4 MEG 15015 7 70088 4 SCR 10 32 X 1 2 PPHMS SS NP 8 02476 1 TOOL GROUT CLEANER 9 140653 2 BRUSH FLOOR TOOL 10 57090 4 NUT 10 32 HEX NYLOCK SS 11 140652 2 BRKT BRUSH MOUNT 12 70626 4 SCR 10 X 3 4 PPHST HI LO BLK 13 47431 REF KIT GROUT CLEANER ...

Page 50: ...TOOLS HIGH PRESSURE WAND OPTION 980146 02 07 04 5 27 ...

Page 51: ...6012 1 NIPPLE 1 4 FPT QD 2 39641 1 HOSE 1 8 MPT X 1 8 MPT X 6 L 3 70195 1 SCR 10 32 X 1 25 PPHMS SS 4 84189 1 VALVE 500 PSI W CLAMP 5 39640 1 HOSE 1 8 MPT X 1 8 MPT X 38L 6 270 11 1 NIPPLE 1 8 FPT QD FEM BRASS 7 02480 1 TOOL ALUMINUM WAND 8 57090 1 NUT 10 32 HEX NYLOCK SS 9 47432 REF KIT HIGH PRESSURE WAND ...

Page 52: ...TOOLS CARPET TOOL OPTION 980146 02 07 04 5 29 ...

Page 53: ... PART NO QTY DESCRIPTION SERIAL NO FROM NOTES 1 270 11A 1 NIPPLE 1 8 FPT QD MALE BRASS 2 39642 1 HOSE 1 8 MPT X 1 4 FPT X 12L 3 31016 1 ELBOW 1 4 NPT STREET 4 87015 4 WASHER 9 16 ID X 1 06 OD SS 5 44080 1 JET 1 4 H VV 11003 6 47433 REF KIT CARPET TOOL ...

Page 54: ...nt warranty followed by 50 replacement value for life WARRANTY ON CHEMICAL USE Improper use of chemicals voids warranty and Century 400 s liability Defoamer is to be used in all Century 400 machines Dry cleaning solvents cannot be used in any Century 400 machine If used fire and or pump damage could result White vinegar should be pumped through the machine 1 time a week to prevent mineral scaling ...