1.2 STANDARD AND OPTIONAL COMPOSITION 

DIATERMO 

Code 

GIMA 

Code 

LED 

description 

MB122 MB160 MB132 

Electrosurgical unit code GIMA 

30540 30541 30544 

Electrosurgical unit code LED 

GMA10100.20A GMA10100.30A GMA10300.10A 

30644 00498.04 

Bipolar 

adpter 

 

 

 

30560 

00500.L11 

Needles for micro-surgery  

 

 

/10 

00100.05 

Power supply cable 2m 3x1mm GB-IEC 

 

 

 

00100.00 

Power supply cable 2m 3x1mm ITALY-IEC 

 

 

 

00100.03 

Power supply cable 2m 3x1mm SIEMENS-IEC 

/1 

/1 

/1 

00100.04 

Power supply cable 2m 3x1mm USA-IEC 

 

 

 

00100.01 

Power supply cable 5m 3x1.5mm SIEMENS-IEC 

 

 

 

30563 

00404.06 

Cable for connection disposable/5365 neutral plate  

/1 

/1 

/1 

30561 

00404.01 

Cable for connection neutral plate 5046 

 

 

 

30508 

00500.L8 

Noose electrode (L8) (5pcs) 5 cm 

 

 

 

30528 

00500.L8/L 

Noose electrode (L8/L) (5pcs) 10 cm 

 

 

 

30507 

00500.L7 

Drop electrode (L7) (5pcs) 5 cm 

 

 

 

30527 

00500.L7/L 

Drop electrode (L7/L) (5pcs) 10 cm 

 

 

 

30671 

0210 

Disposable blade electrode 7 cm 

 

 

 

30675 

0210/L 

Disposable blade electrode 15 cm 

 

 

 

30672 

0230 

Disposable ball electrode 7 cm 

 

 

 

30676 

0230/L 

Disposable ball electrode 15 cm 

 

 

 

30670 

0220 

Disposable needlel electrode 7 cm 

 

 

 

30674 

0220/L 

Disposable needlel electrode 15 cm 

 

 

 

30503 

00500.L3 

Loop electrode 

 4mm (L3) (5pcs) 5 cm 

 

 

 

30523 

00500.L3/L 

Loop electrode 

 4mm (L3/L) (5pcs) 10 cm 

 

 

 

30504 

00500.L4 

Loop electrode 

 8mm (L4) (5pcs) 5 cm 

 

 

 

30524 

00500.L4/L 

Loop electrode 

 8mm (L4/L) (5pcs) 10 cm 

 

 

 

30502 

00500.L2 

Bent thin wire electrode (L2) (5pcs) 5 cm 

 

 

 

30522 

00500.L2/L 

Bent thin wire electrode (L2/L) (5pcs) 10 cm 

 

 

 

30506 

00500.L6 

Bent thick wire electrode (L6) (5pcs) 5 cm 

 

 

 

30526 

00500.L6/L 

Bent thick wire electrode (L6/L) (5pcs) 10 cm 

 

 

 

30509 

00500.L10 

Bent ball electrode 

 3mm (L10) (5pcs) 5 cm 

 

 

 

30529 

00500.L10/L 

Bent ball electrode 

 3mm (L10/L) (5pcs) 10 cm 

 

 

 

30505 

00500.L5 

Bent hook electrode (L5) (5pcs) 5 cm 

 

 

 

30525 

00500.L5/L 

Bent hook electrode (L5/L) (5pcs) 10 cm 

 

 

 

30501 

00500.L1 

Straight thin wire electrode (L1) (5pcs) 5 cm 

 

 

 

30521 

00500.L1/L 

Straight thin wire electrode (L1/L) (5pcs) 10 cm 

 

 

 

30510 

00500.L9 

Straight ball electrode 

 3mm (L9) (5pcs) 5 cm 

 

 

 

30530 

00500.L9/L 

Straight ball electrode 

 3mm (L9/L) (5pcs) 10 cm 

 

 

 

30564 

2818C 

Conductive rubber neutral electrode 

 

 

 

30561 

5046 

Steel neutral electrode for 00404.01 

 

 

 

5365 

5365 

Steel neutral electrode for 00404.06 

/1 

/1 

/1 

30562 

0350 

Disposable neutral electrode 

 

 

 

30565 

F7920 

Disposable split neutral electrode 

 

 

 

28323 

00602.100 

Fasting bandage 100 cm 

 

 

 

30531 

00500.00/L 

Kit of assorted electrodes (10pcs) 10cm 

 

 

 

30500 

00500.00 

Kit of assorted electrodes(10pcs) 5cm 

 

/1 

/1 

00500.03 

Kit of assorted electrodes (6pz) (L1-2-4-7-9-10) 5cm 

/1 

 

 

EQUIKIT1 

EQUIKIT1 

Kit for equipotential connection 

 

 

 

30551 

Handle with finger switches GIMA 

 

 

 

30518 

Handle without finger switches GIMA 

   

 

 

30552 

00201.01 

Handle for microsurgical needle 

 

 

/1 

30550 

Handle with finger switches GIMA 

/1 

/1 

 

30549 

2835A 

Reusable handle with finger switches ROI 

 

 

/1 

30519 BWA435-030 

Reusable 

handle 

without finger switches 

 

 

 

M30540 

MA036IGBE 

Manual of instructions 

/1 

/1 

/1 

30568 

00300.00 

Not waterproof foot switch 

/1 

/1 

/1 

30571 

00302.00 

Waterproof foot switch 

 

 

 

30570 

00301.03 

Double waterproof foot switch 

 

 

 

F7520 

Electrode cleaning sponge 

 

 

 

/pcs= STANDARD 

 

= OPTIONAL

 

1.3 GENERAL DESCRIPTION  

DIATERMO MB122, MB160 

and 

MB132

 are electro-surgical equipments suited to deliver current 

for monopolar cut, soft coagulation, forced coagulation or bipolar coagulation. The current can be 
delivered for the whole time of activation of the output circuit or, with the model MB132, for an 
interval of time which can be preset. The preset time delivery can repeated from 2 to 9 times. 

Summary of Contents for DIATERMO MB122

Page 1: ...MANUALE D ISTRUZIONI INSTRUCTION S MANUAL MANUAL DE INSTRUCCIONES DIATERMO MB122 MB132 MB160 M30540 MA036IGBEa...

Page 2: ...rsonnel at all times All the safety instructions and advice notes are to be observed Be sure that these operating instructions is furnished together the equipment when this is transferred to other ope...

Page 3: ...D COAG 18 4 4 4 Corrente per Coagulazione Profonda SOFT COAG 18 4 4 5 Corrente di Coagulazione Bipolare BIPOLAR 18 4 5 SEGNALAZIONE DI TEMPO DI EROGAZIONE ECCESSIVO OVT 19 4 6 SEGNALAZIONE DI ECCESSIV...

Page 4: ...on Current SOFT COAG 35 4 4 5 Bipolar Coagulating Current BIPOLAR 35 4 5 SIGNALING OF EXCESSIVE TIME OF DELIVERY OVT 36 4 6 SIGNALING OF EXCESSIVE IMPEDANCE IN THE CIRCUIT OF NEUTRAL ELECTRODE OC 36 4...

Page 5: ...de la Coagulacion BIPOLAR 53 4 5 EL SE ALAR DE LA POCA EXCESIVA DE LA SALIDA OVT 54 4 6 EL SE ALAR DE LA IMPEDANCIA EXCESIVA EN EL CIRCUITO NEUTRAL DEL ELECTRODO OC 54 4 7 AJUSTE DEL NIVEL AC STICO DE...

Page 6: ...room It has foreseen its use in the monopolar cut cut coagulated or coagulation mode or in bipolar coagulation mode The equipment is conceived for being used in the following sectors DIATERMO descrizi...

Page 7: ...00500 L10 Bent ball electrode 3mm L10 5pcs 5 cm 30529 00500 L10 L Bent ball electrode 3mm L10 L 5pcs 10 cm 30505 00500 L5 Bent hook electrode L5 5pcs 5 cm 30525 00500 L5 L Bent hook electrode L5 L 5pc...

Page 8: ...effects can be precisely controlled it can be used safely without damage to the bone but since good coagulation while cutting is one of principal benefits of using electrosurgery a current with a cert...

Page 9: ...ectioning of the biological tissue due to the passage of HF current concentrated on the tips of the bipolar forceps When the HF current is applied to the tissue between the two tips of the forceps an...

Page 10: ...le or metallic support The use of antistatic sheets is advised Avoid the skin to skin contact for example between arm and body of the patient Insert an interface material like dry surgical gauze Moreo...

Page 11: ...e lack of efficient connection to earth of the installation Operation without a protective earth connection is forbidden Before connect the equipment ascertain that the required voltage showed on the...

Page 12: ...aporate before putting in operation the unit Don t exceed the temperature environment or the allowed moisture Environmental conditions Temperature 10 40 C Relative moisture 30 75 Pressure 70 106k Pa W...

Page 13: ...done pressing the correspondent pushbutton on the unit press the blue foot switch to pre set and deliver the coagulating current the choice between FORCED COAG SOFT COAG or BIPOLAR must be done pressi...

Page 14: ...work 4 1 1 MANUFACTURER S IDENTIFICATION DATA DIATERMO MB122 MB160 and MB132 HF electrosurgical unit are designed manufactured and tested by the LED SpA in its own laboratories in Aprilia LT Italy 4 1...

Page 15: ...ion keyboard 5 Alarm warning for current delivery over time 6 OC open circuit alarm 7 Handle connection 8 Return plate connection MB132 1 Mains switch 2 Pulse time selector 3 Pulse repetition selector...

Page 16: ...t when a deep coagulation together the cut is desired This current is made by sine current e suited for the cut associated to low voltage current suited for coagulation soft coag With this blending a...

Page 17: ...indications 1 Switch on the unit through the mains switch while the CUT pushbutton is maintained pressed 2 When the unit has finished to check internal parameters on the display CUT appears the messa...

Page 18: ...push the CONT push button to do it 4 10 2 REPETITION OF TIMED DELIVERY The timed high frequency current emission can be automatically repeated from 2 to 9 times each time one foot switch or one hand s...

Page 19: ...ided with line fuses WARNING before switch on the unit operator has to verify that requested mains voltage corresponds to the voltage available from the electrical net 4 11 2 PEDAL CONNECTOR On the le...

Page 20: ...0 1050 1050 15 Maximum output voltage BLEND Vpp on5 2k9 1050 1050 1050 15 Maximum output voltage FORCED Vpp on5 2k9 1050 1050 1050 15 Maximum output voltage SOFT Vpp on5 2k9 540 540 540 15 Maximum out...

Page 21: ...of the supplier of each item When original reusable accessories supplied by LED S p A are applied the cleaning by using soft cleanser and sterilization through steam sterilisation at 121 C is recommen...

Page 22: ...s properly grounded Assure that all the accessories that should be used are available and sterilised Check by disconnecting the reference electrode cable the functioning of the OC light and sound alar...

Page 23: ...edance load 100 2000 SOFT Diagrams of half and maximum output power versus impedance load 10 1000 BIPOLAR Diagrams of output power CUT versus nominal value Diagrams of output power BLEND versus nomina...

Page 24: ...2000 SOFT Diagrams of half and maximum output power versus impedance load 10 1000 BIPOLAR Diagrams of output power CUT versus nominal value Diagrams of output power BLEND versus nominal value Diagrams...

Page 25: ...end of the life the present product mustn t be eliminated as urban refusal but it must be eliminated in a separated collection If the product is eliminated in unsuitable way it is possible that some p...

Reviews: