23

ENGLISH

B.  Variations in blood pressure:

Individual blood pressures vary great-
ly both on a daily and a seasonal ba-
sis. 
These variations are even more pro-
nounced in hyper tense patients.
Normally the blood pressure rises 
while at work and is at its lowest dur-
ing sleeping period.

(hyper tense: means a person who 
has high blood pressure symptom.)

The graph below illustrated the variations in blood pressure over a whole day with meas-
urement taken every five minutes.
The thick line represents sleep. The rise in blood pressure at 4 PM (A in the graph) and 12 
PM (B in the graph) correspond to an attack of pain.  

PRECAUTIONS

* Do not use this manual and product as a substitute for advice, diagnosing or treating 

a health problem or prescribing any medication by your doctor. If you have a medical 
problem, promptly consult your healthcare provider.

*  Read the Instruction Manual thoroughly before measuring and keep it at hand for your 

reference at any time.

*  This device uses the oscillometric method to measure systolic and diastolic blood pres-

sure as well as your heart rate. It’s recommended for use by people over the age of 18 
and not to be used on infant or children.

*  The device is designed for home use and not suitable for clinical use. 

• Do not take a measurement in a low (less than 41°F/5°C) and high (more than 104°F/ 

40°C) temperature, nor in a place outside humidity ranges (15% ~ 93% R.H.), and at-
mospheric pressure ranges (700  ~ 1060 hPa) or you may get inaccurate readings.

• Wait 30 ~ 45 minutes before measurement if you’ve just consumed caffeinated beverag-

es or smoked cigarettes.

• Rest at least 5 ~ 10 minutes before taking a measurement.
• To allow your blood vessels to return to the condition prior to taking the measurement, 

please wait at least 3 ~ 5 minutes in between measurements. You may need to adjust 
the wait time according to your personal physiological situation.

• We recommend you using the same arm (preferably the left arm) and measuring around 

the same time each day.

• Sit down comfortably and place your elbow on the table with your feet flat on the floor. 

Please do not cross your legs during measurements.

• Keep the device at heart level. Relax your hand with the palm facing up.
• Perform measurements in a quiet and relaxed environment at room temperature.

Summary of Contents for 32924n

Page 1: ...NSIOM TRE BRACHIAL DE LA PRESSION ART RIELLE MONITOR AUTOM TICO DE BRAZO DE PRESI N SANGU NEA M32924 M Rev 5 02 22 PROFESSIONAL MEDICAL PRODUCTS 0476 Gima S p A Via Marconi 1 20060 Gessate MI Italy gi...

Page 2: ...ded by your doctor You are not to use the information contained herein or this product for diagnosing or treat ing a health problem or prescribing any medication If you have or suspect that you have a...

Page 3: ...clinic is often asso ciated with a phenomenon called White Coat Hypertension where the patient becomes nervous or anxious thus raising his blood pressure There are also numerous other factors that mig...

Page 4: ...blood pres sure as well as your heart rate It s recommended for use by people over the age of 18 and not to be used on infant or children The device is designed for home use and not suitable for clin...

Page 5: ...ofessional before using the device This product is not suitable for people with arrhythmias and pregnant women Blood pressure measurements taken with this device are equivalent to those obtained by a...

Page 6: ...mponents Caution Substitution of a component different from that supplied might result in measurement error 25 ENGLISH 6V 1A AC Adapter Excluded MEMORY BUTTON AA 1 5V ALKALINE BATTERY X 4 START STOP B...

Page 7: ...ned Pulse Symbol Once pulse is detected the symbol flashes with each pulse beat Our suggestion Please do not talk or move during meas urements Irregular Heartbeat Detector This symbol appears for 1 mi...

Page 8: ...gularity is detected during measurement often we recommend you seek medical advice As a safeguard we recommend that if you have arrhythmias such as atrial or ventricular premature beats and atrial fib...

Page 9: ...59 90 99 Red Provide advice about lifestyle modification Hypertension and confirm within two months High Normal 130 139 85 89 Orange Provide advice about lifestyle modification and recheck in one year...

Page 10: ...ith new ones and do not mix new and old batteries Do not mix alkaline standard carbon zinc or rechargeable cadmium batteries either It may shorten the battery life or cause the device to malfunction R...

Page 11: ...rachial artery approximately 1 inch 2 3 cm above the elbow on the inside of your left arm to determine where your strongest pulse is Slide the end of arm cuff furthest from the tube through the metal...

Page 12: ...our arm is wounded or injured MEASUREMENT PROCEDURE Switch on the monitor A Press button to switch on the monitor B All segments appear on the screen Setting year date and time A Press button YEAR fla...

Page 13: ...ector symbol with date and time for 1 minute E Without any operation for 1 minute device automatically shuts off MEMORY FUNCTION Storing data After each measurement the systolic and diastolic pressure...

Page 14: ...ng chemicals to clean the device Use only a dry cloth to wipe the cuff Do not attempt to disassemble or change any parts of the monitor including arm cuff due to substitution of a component different...

Page 15: ...ol appears when blood pressure value displayed is excessively low or high Cuff has been placed incorrectly Wrap the cuff properly so that it is positioned correctly Did you talk or move during measure...

Page 16: ...Total for 3 Users Unit Dimensions 5 51 x 4 09 x 1 97 inch L x W x H 140 x 104 x 50 mm L x W x H Unit Weight 8 73 0 35 oz 247 5 10 g Cuff and Batteries Excluded Cuff Size 23 33 cm 9 13 inch Storage Tr...

Page 17: ...caused by electromagnetic interference between elec trical and electronic equipments do not use the device near a mobile phone or microwave oven At least keep a maximum output power of 2 W yields and...

Page 18: ...8 kV contact discharge 15 kV air discharge In the case of air discharge testing the climatic conditions shall be within the following ranges Ambient Temperature 15 C 35 C Relative Humidity 30 60 Power...

Page 19: ...distance based on RISK MANAGEMENT and using higher IM MUNITY TEST LEVELS that are appro priate for the reduced minimum sepa ration distance Minimum separation distances for higher IMMUNITY TEST LEVELS...

Page 20: ...18 Hz 28 870 930 1720 Pulse modulation 217 Hz 28 1845 1970 2450 Pulse modulation 217 Hz 28 5240 Pulse modulation 217 Hz 9 5500 5785 NOTE If necessary to achieve the IMMUNITY TEST LEVEL the distance b...

Reviews: