QUICK GUIDE 

|

 

PIPETMAN® G

Introduction

 

PIPETMAN® G is a fully adjustable air-displacement, 

pipette that is used with disposable tips. 
Eight single channel models cover a volume range from 

0.2 µL to 10 mL. 
Eight multichannel models cover a volume range from  

1 µL to 300 µL. 

NOTICE

PIPETMAN G is identified by a visual blue ring.

PIPETMAN G pistons need to be lubricated.

Parts Checklist

Single models

 

PIPETMAN G

 

PIPETMAN G Quick Guide

 

Safety bag

 

Dual-position adapter (for P2G and P10G models 

only, refer to

 Fitting the Tips 

on page 6)

 

Certificate of Conformity (including barcode 

sticker)

Multichannel models

 

PIPETMAN G

 

PIPETMAN G Quick Guide

 

Safety bag

 

Ejector spacers for D10 tips (for Px10G models 

only, refer to 

Ejector Spacers for PIPETMAN G 

Multichannel 10 uL

 on page 6)

 

Certificate of Conformity (including barcode 

sticker)

GLP Compliant

The 

serial number

 is engraved 

on the body of the pipette. It 
provides unique identification 
of your pipette and the date 
of manufacture. For more 
details, refer to 

PIPETMAN G 

User’s Guide LT801122.
Ex: AA10369

The 

barcode 

on the box and 

the Certificate of Conformity 
provide traceability of your 
pipette.

Serial number

Figure 1

Serial number location

Summary of Contents for PIPETMAN G

Page 1: ...Quick Guide EN G...

Page 2: ...y refer to Fitting the Tips on page 6 Certi cate of Conformity including barcode sticker Multichannel models PIPETMAN G PIPETMAN G Quick Guide Safety bag Ejector spacers for D10 tips for Px10G models...

Page 3: ...and precision The data provided in the Maximum Permissible Errors table on page 5 were obtained using PIPETMAN DIAMOND Tips These values are guaranteed only when genuine PIPETMAN DIAMOND Tips are used...

Page 4: ...SYSTEMA TIC ERROR L RANDOM ERROR L PIPETMAN G SINGLE CHANNEL P2G P N F144054M WITH D10 OR DL10 TIPS 0 2 0 5 1 2 0 024 0 025 0 025 0 030 0 012 0 012 0 012 0 014 0 08 0 08 0 08 0 08 0 04 0 04 0 04 0 04...

Page 5: ...e setting slowly reach the required setting making sure to not overshoot the mark When increasing the volume setting pass the required value by 1 3 of a turn and then slowly decrease to reach the volu...

Page 6: ...122 ACCESSORIES Fitting the Tips on P2G and P10G Models NOTE For the P2G and P10G models a dual position adapter plastic is required to fit DL10 tips long tips or D10 tips short tips The metallic rod...

Page 7: ...rst volume of liquid and then dispensing it back into the same vessel or to waste Subsequent volumes you pipette will have levels of accuracy and precision within specifications Ejector Spacer for PIP...

Page 8: ...d touching the tip s orifice First stop Second stop Dispense 1 Place the end of the tip against the inside wall of the recipient vessel at an angle of 10 to 40 2 Press the push button slowly and smoot...

Page 9: ...p ejector tip holder seal and O ring NOTICE PIPETMAN P2G and P10G should not be disassembled You may only replace the push button tip ejector and its dual position adapter With these pipettes if the t...

Page 10: ...or refund of the purchase price paid for such pipettes Routine cleaning control and recalibration are not covered under the warranty The replacement of wearing parts such as seals O rings broken pist...

Page 11: ...11 PIPETMAN G QUICK GUIDE NOTES...

Page 12: ...www gilson com contactus LT801624 C 2019 Gilson Inc All rights reserved...