Gill Instruments Ltd
000
No inputs enabled
001
1 input enabled
010
2 inputs enabled
011
3 inputs enabled
100
4 inputs enabled
101
5 inputs enabled
110
6 inputs enabled
111
Not
used
Bit
3
0 Reserved
1 Reserved
Bits 5,4
00
Reserved
01
Reserved
10
Reserved
11
Reserved
Bits
7,6
00
Reserved
01
Reserved
10
Reserved
11
Reserved
Address 04 - Error code history
Bit
Function
0 Reserved
1 Reserved
2 Reserved
3 Reserved
4
Non-volatile memory error
5 PRT
failed
6 Reserved
7 Reserved
The error history is cleared when the user enters interactive mode.
Address 05 - Transducer gain levels
Bits
1,0
00
Channel pair 1 nominal
01
Channel pair 1 @ 50%
10
Channel pair 1 @ 90%
11
Channel pair 1 @ 100%
Bits
3,2
00
Channel pair 2 nominal
01
Channel pair 2 @ 50%
10
Channel pair 2 @ 90%
11
Channel pair 2 @ 100%
Bits
5,4
00
Channel pair 3 nominal
01
Channel pair 3 @ 50%
10
Channel pair 3 @ 90%
11
Channel pair 3 @ 100%
HS-50 Research Anemometer
Page 27
Issue 02
Doc. No. 1199-PS-0032
November 2004
Summary of Contents for HS-50