Gill Instruments Ltd
0
Transducer pair 1 failed.
1
Transducer pair 2 failed
2
Transducer pair 3 failed
3 Reserved
4
Non-volatile memory error
5 PRT
failed
6 Reserved
7 Reserved
Address 01 - Anemometer configuration
Bit
Function
0 Reserved
1 PRT
fitted
2 Reserved
3 Inclinometer
fitted
4
0
U, V, W axis definition (U aligned with transducer axis 1 when viewed from
above)
1
U', V', W' axis definition (U' aligned with the spar)
5 Reserved
6 Reserved
7 Reserved
Address 02 - Data output configuration 1
Bits
1,0
00
Wind mode UVW
01
Wind mode axis
10
Polar 360 wrap
11
Polar 540 wrap
Bits
3,2
00
±10ms-1 Full Scale Deflection
01
±20ms-1 Full Scale Deflection
10
±30ms-1 Full Scale Deflection
11
±60ms-1 Full Scale Deflection
Bits
5,4
00
SOS report off
01
SOS report speed of sound
10
SOS report sonic temp. K
11
SOS report sonic temp. C
Bits
7,6
00
PRT temp. off
01
PRT temp. K
10
PRT temp. C
11 Reserved
12
Address 02 is repeated for 8 samples after a power on reset or exit from ‘Interactive Mode’ to allow
the analogue output card or custom PC software to recognise the output configuration.
Address 03 - Data output configuration 2