Model: GVH-C & GVH-F
Installation
* Appliance(s) exceeding 50 Amps must be powered by a separate circuit from the Hood, but be interlocked
through the Hood contactor coil.
** Appliance provided and rated separately from Hood.
2.05
Electrical Specification
• Food service equipment must be properly grounded in accordance with local code, or in the absence of local
code, with the
National Electrical Code, ANSI/NFPA 70
.
Improper grounding may result in electrical shock to
users. Check local electrical code to ensure proper grounding.
•
Always consult a certified electrician, or other qualified service technician, prior to installation to ensure that
electrical circuits are of sufficient rating to power the hood and appliance load.
• Improper installation, adjustment, alteration, service or maintenance could result in serious injury or possible
death, equipment or property damage, and could void the warranty.
Hood & Appliance** on same 208-240V Circuit
Voltage
Hz
Phase
Field Provided Appliance
Load (Amps)
Hood Load
(Amps)
Branch Circuit Breaker
Hood & Appliance on Same
Circuit
208-240
60
1 or 3
0 - 10.5
5
20
10.6 - 14.5
5
25
14.6 - 22.5
5
35
22.6 - 38.5
5
55
38.6 - 46.5
5
65
46.7 - 50
*
5
75
Hood Only - Appliance on Separate Circuit, Interlocked Through Separate Contactor
Voltage
Hz
Phase
Hood Load
(Amps)
Breaker
208-240
60
1
5
10
Summary of Contents for GVH-C
Page 2: ......
Page 4: ......
Page 13: ...3 Model GVH C GVH F Introduction 1 04 1 Overall Dimensions GVH F Floor Stand Version ...
Page 18: ...8 Model GVH C GVH F Installation 2 03 2 GVH Floor Stand Hood GVH F ...
Page 34: ...Model GVH C GVH F Overview 24 1 5 2 4 3 8 9 3 01 Control Panel 6 7 ...
Page 49: ...39 Model GVH C GVH F Operation Filter Maintenance ...
Page 56: ...46 Model GVH C GVH F Troubleshooting ...
Page 64: ...54 Parts List Model GVH C GVH F 7 05 Under Hood Components 2 1 4 3 ...
Page 66: ...56 Model GVH C GVH F Parts List ...
Page 67: ......