36
Model: FSH-4 Hood
Operation & Filter Maintenance
4.04.1
Baffle Filter Cleaning
Ideally, grease baffle filters should be cleaned daily. Remove and clean in sink with a mild, bio-degradable,
degreasing cleaner
(Giles recommends Simple Green® Crystal Foaming Spray Cleaner)
. Rinse and dry thoroughly.
Reinstall dry filters in the unit. Generally, baffle filters can be washed in a dishwasher.
Ensure that filters are completely dry before reinstalling in Hood. NEVER PLACE A WET FILTER INTO THE HOOD!
Stainless steel Baffle Filters are fabricated from thin guage metal that has potential to
present sharp edges. Exercise due care when handling and cleaning the Filters to avoid
injury.
It is recommended that heavy-duty rubber gloves be worn
.
4.04.2
E.A.C. Filter Cell Cleaning
Continued on Next Page
The E.A.C. collector cell is sustainable and renewable; it should last for years if cleaned and handled properly. To
maintain peak performance, It
MUST BE CLEANED DAILY
; not doing so can lead to an interruption of appliance
operation, premature failure of the electronic cleaning system, or reduced useful life of consumable charcoal filters.
Follow the procedures detailed below for effective cleaning.
IMPORTANT: The cell CANNOT withstand washing in commercial dishwashing equipment, and some commercial
cleaners/detergents will cause oxidation, or create a layer of contamination, on the aluminum collection fins that
can lead to system malfunction and result in interruption of power to appliances being served by a ventless hood
unit.
Two (2) different cleaning methods are endorsed by
GILES Food Service,
as follows.
• Preferred
spray foam method
uses
Simple Green® Crystal Foaming Spray Cleaner/Degreaser.
A readily
available foaming aerosol that is an exceptionally effective cleaner, as well as being safe for use on
aluminum (
NSF approved,
food-grade, non-toxic, and biodegradable). Cleaning the E.A.C. cell is quick
and easy with this convenient ready-to-use cleaner. A complimentary sample is supplied with new
equipment. It can be ordered from
Giles,
item #41510 (12-count case)
.
When used as directed, a case
of cleaner should approximately be a 4 to 5 week supply, depending on equipment model.
• Alternative
soaking method
uses a diluted solution of
Simple Green® Pro-HD
and water
.
Although not as
convenient as the spray method, requiring more planning and time, the procedure has proven to be very
satisfactory for cleaning E.A.C. collector cells for many years. This product has the same characteristics of the
spray product, but requires mixing with water before use ...
dilution factor is 1:12
, e.g. mix 1/2 gal. of cleaner
with 6 gals. of water.
The E.A.C. collector cell contains parts fabricated from thin gauge sheet metal that can
potentially have sharp edges, which may cause cuts if not handled properly. To avoid injury,
exercise due care when handling and/or cleaning the cell.
It is recommended that heavy-
duty rubber gloves be worn as a precaution
.
With proper care, cleaning, and handling, the E.A.C. collector cell is designed to provide years of service.
Summary of Contents for FSH-4 Hood
Page 2: ......
Page 4: ......
Page 14: ...4 Model FSH 4 Hood Introduction ...
Page 28: ...Model FSH 4 Overview 18 1 2 3 4 6 7 3 01 Control Panel 5 ...
Page 30: ...20 Model FSH 4 Overview 5 2 1 3 4 6 7 8 1 5 3 4 3 02 Filter Chamber Exhaust 9 9 Not shown ...
Page 34: ...24 Model FSH 4 Overview ...
Page 56: ...46 Model FSH 4 Hood Troubleshooting ...
Page 60: ...50 Model FSH 4 Hood Parts List Not shown 6 7 2 9 1 8 4 5 6 8 7 2 1 3 5 7 03 Hood Front Opened ...
Page 62: ...52 Model FSH 4 Hood Parts List Not shown 4 5 2 1 3 1 7 04 Under Hood Filters Light ...
Page 64: ...54 Model FSH 4 Hood Parts List Not shown 7 05 Doors Front Panel 11 8 7 9 10 1 4 2 6 3 5 12 ...
Page 66: ...56 Model FSH 4 Hood Parts List ...
Page 67: ......