44
Model: FSH-3.5
&
FSH-4
Troubleshooting
6-1
Troubleshooting Procedures (Cont’d.)
Problem
Probable Cause
Corrective Action
Appliance will not heat
• Hood power
ON
•
FILTER MISSING
light
ON
•
APPLIANCE POWERED
light
OFF
a. Baffle Filter missing
a. Install Baffle Filter
b. Baffle Filter not installed
properly
b. Reinstall Baffle Filter
c. Charcoal Filter missing
c. Install Charcoal Filter
Appliance will not heat
• Hood power
ON
•
FILTER CLOGGED
light
ON
•
APPLIANCE POWERED
light
OFF
• Alarm emitting a continuous tone
a. Charcoal Filter clogged
a. Replace Charcoal Filter
b. Baffle Filter clogged
b. Clean Baffle Filter
c. Clogged filter switch out of
adjustment
c. Adjust clogged switch only.
(initial start-up switch bad)
d. Kinked vacuum line
d. Remove vacuum line kinks
e. Fan running slow
e. Check voltage
Appliance will not heat
• Hood power
ON
•
CHECK
and/or
WASH
LED’s
ON
•
APPLIANCE POWERED
light
OFF
• Alarm emitting an intermittent
tone
a. EAC shorted
a. Repair EAC
b. EAC dirty
b. Clean EAC
c. EAC power supply faulty
c. Replace EAC power supply
d. EAC wires shorted
d. Check voltage
e. Bad contact plate
e. Replace contact plate
f.
EAC module faulty
f.
Replace EAC module
g. EAC ionizer wire broken or
missing
g. Replace ionizer wire
Summary of Contents for FSH-3.5
Page 2: ......
Page 4: ......
Page 18: ...8 Model FSH 3 5 FSH 4 Installation 2 03 3 Hood Mounting Detail Free Standing STEP 1 STEP 2 ...
Page 28: ...18 Model FSH 3 5 FSH 4 Installation NOTES ...
Page 30: ...Model FSH 3 5 FSH 4 Overview 20 3 01 Control Panel 7 6 5 4 2 1 ILS Only 6 5 4 3 8 10 9 ...
Page 36: ...26 Model FSH 3 5 FSH 4 Overview Notes ...
Page 48: ...38 Model FSH 5 FSH 6 Operation Filter Maintenance Notes ...
Page 52: ...42 Model FSH 3 5 FSH 4 Hood Cleaning and Maintenance Notes ...
Page 60: ...50 Model FSH 3 5 FSH 4 Parts List 7 4 Baffle Filters and Switches 2 1 Not shown 3 4 5 ...
Page 66: ...56 Model FSH 3 5 FSH 4 Parts List Notes ...
Page 67: ...Model FSH 3 5 FSH 4 ...