Operation & Filter Maintenance
4-02.17. Charcoal Filter Replacement
•
NEVER attempt to clean and re-use the Charcoal Filter. This could cause damage to the unit.
!
WARNING
Replace the Charcoal Filter every 30 days. Use Replacement Part No.
.
Please take the time to record installation date in space provided on the new filter label.
4-03.
Filter Alarm Chart
Alarm Sound
What will happen
Filter
affected
Cause
Solution
See Section
Continuous tone
Alarm sounds, “Clogged Filter”
lamp illuminates and power to the
appliance is shutdown, “Appliance
Powered” light is
OFF
.
(If ILS model, the hood fan will also
shutdown)
Charcoal
or
Pre-Filter
Filter dirty Replace Filter
4-02.15. &
4-02.17.
or
4-02.07 &
4-02.09
Continuous tone
Alarm sounds, “Clogged Filter”
lamp illuminates and power to the
appliance is shutdown, “Appliance
Powered” light is
OFF
.
(If ILS model, the hood fan will also
shutdown)
Baffle
Filter dirty Clean Filter
4-02.03. &
4--02.05
Intermittent tone
“Check” and/or “Wash” LED’s will
illuminate, alarm sounds, after
approx. 2 minutes, power to the
appliance is shutdown, “Appliance
Powered” light is
OFF
.
(If ILS model, the hood fan will also
shutdown)
E.A.C.
Filter dirty Clean Filter
4-02.11. and
4--02.13
Summary of Contents for FSH-3.5
Page 2: ......
Page 4: ......
Page 18: ...8 Model FSH 3 5 FSH 4 Installation 2 03 3 Hood Mounting Detail Free Standing STEP 1 STEP 2 ...
Page 28: ...18 Model FSH 3 5 FSH 4 Installation NOTES ...
Page 30: ...Model FSH 3 5 FSH 4 Overview 20 3 01 Control Panel 7 6 5 4 2 1 ILS Only 6 5 4 3 8 10 9 ...
Page 36: ...26 Model FSH 3 5 FSH 4 Overview Notes ...
Page 48: ...38 Model FSH 5 FSH 6 Operation Filter Maintenance Notes ...
Page 52: ...42 Model FSH 3 5 FSH 4 Hood Cleaning and Maintenance Notes ...
Page 60: ...50 Model FSH 3 5 FSH 4 Parts List 7 4 Baffle Filters and Switches 2 1 Not shown 3 4 5 ...
Page 66: ...56 Model FSH 3 5 FSH 4 Parts List Notes ...
Page 67: ...Model FSH 3 5 FSH 4 ...