45
Troubleshooting
FSH
−
2
−
PH
6.01
Troubleshooting Procedures
−
continued
Problem
Probable Cause
Corrective Action
Fryer will not power
up:
•
[HOOD POWER]
light
ON
•
[
FILTER MISSING]
light
ON
•
[FRYER POWER]
light
OFF
a. Baffle filter is missing or not
properly installed
Install filter / check positioning.
b. Charcoal filter is missing or not
properly installed
Install filter / check positioning.
c. Faulty filter switches.
Test & replace as needed.
Fryer will not power
up:
•
[HOOD POWER]
light
ON
•
[
FILTER MISSING]
light
OFFN
•
[FRYER POWER]
light
OFF
• No alarm sounding
a. Fire Suppression system is not
armed.
Contact Ansul service company.
b. Ansul switch is faulty
Contact Ansul service company.
Fryer will not power
up:
•
[HOOD POWER]
light
ON
•
Continuous (steady) tone
alarm
sounding.
•
[FRYER POWER]
light
OFF
a. Baffle or charcoal filter clogged
Replace charcoal filter with new •
Clean baffle filter.
b. Hood exhaust outlet excessively
block
Clear of any obstructions.
c. Vacuum switch is out of
adjustment
Test & adjust vacuum switch.
d. Kinked or blocked vacuum line
Remove vacuum line kinks or
blockage.
e. Fan running slow or blades are
loaded with grease build
up.
Check voltage and inspect blower;
clean if needed
Fryer will not power
up:
•
[HOOD POWERED]
light
ON
•
[WASH]
light
ON
•
Intermittent (beeping) tone
alarm
sounding.
•
[FRYER POWER]
light
OFF
a. Excessive grease film built up on
collector fins; too dirty
Clean the EAC cell,
Section 4.04.2
.
b. EAC cell is not installed
Install clean EAC cell.
c. EAC driver board is faulty
Test & replace EAC power supply if
needed.
d. Poor connection at contact
plate; dirty contacts, mis
alignment, faulty contacts.
Check cell position, clean contacts,
inspect contact plate & replace if
needed.
e. Ionizer wire(s) missing
Replace missing wire(s)
Fryer is ON:
•
[HOOD POWER]
light
ON
•
[CHECK]
light
ON
•
No
alarm sounding, but cell is
NOT
cleaning air
.
a. Ionizer wire broken & touching
chassis.
Replace ionizer wire.
b. Collector fins shorted to ground
by moisture.
Dry cell, determine cause of
moisture, cool air being drawn into
hood creating condensation.
Summary of Contents for FSH-2-PH
Page 4: ......
Page 14: ...4 Introduction FSH 2 PH ...
Page 36: ...26 Overview FSH 2 PH ...
Page 45: ...35 Operation FSH 2 PH NOTES ...
Page 53: ...43 Cleaning Maintenance FSH 2 PH ...
Page 56: ...46 Troubleshooting FSH 2 PH ...
Page 58: ...48 Parts List FSH 2 PH 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Page 64: ...54 Parts List FSH 2 PH Notes ...
Page 65: ......