39
Cleaning & Maintenance
FSH
−
2
−
PH
The
HEPA Filter
is a consumable item which must be replaced periodically (see
Sections 4.02.5, Removal & 4.02.5,
Installation
).
It CANNOT be cleaned and reused.
Typical replacement cycle can vary significantly depending on the
cooking activities (quantity and type of foods cooked). A
HEPA
filter should potentially have a useful service life of
approximately
3 to 4 months
, but this can only be determined by actual use.
If a
HEPA
filter has been in service for a period of time and a clogged filter alarm condition occurs
(see Section 4.03.2)
,
first replace the charcoal filter. If the alarm clears, that is an indication that the
HEPA
filter if still serviceable. Should the
alarm
NOT
clear with the new charcoal filter, the filter probably needs to be replace.
DO NOT attempt to clean and
reuse the HEPA filter.
Use
GILES
replacement
Item No. 41254
. Record the replacement date on new filter.
IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
5.01.4
HEPA Filter Maintenance [HEPA version only]
Hood is available equipped with a replaceable
HEPA
Filter
as an alternative to the electronic air cleaning (E.A.C.) system
with sustainable collector cell.
Charcoal Filter is a single
‐
use, disposable filter. NEVER attempt to clean and reuse; doing so
can cause damage to the unit.
Charcoal filter is a consumable item which must be replaced periodically (see
Sections 4.02.6, Removal & 4.02.7,
Installation
). It
CANNOT
be cleaned and reused. Typical replacement cycle is every
30 to 40 days
, depending on usage.
Use
GILES
replacement
Item No. 30248
. Record replacement date on new filter.
IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
5.01.3
Charcoal Filter Maintenance
3. After preparing the cleaning/degreaser solution, hold the cell by contact plate
,
frame or
handle and carefully place it into the solution, being sure that it is fully submerged.
4. Allow cell to soak for approximately
20 minutes (no more than 30 mins)
, then lift it slightly
and briefly agitate in the solution to help dislodge grease residue.
5. Carefully remove cell from container and perform
Steps 4 thru 6
as explained in
Method (A)
.
NOTE:
A degreaser soaking solution may be used multiple times ... cover container with a lid or other suitable cover when
not in use to prevent contamination. Discard and remake the solution when a greasy film seems to remain floating on
the liquid. When soaking, always ensure that solution completely covers the cell ... add some water if needed.
5.01.2
E.A.C. Filter Cell Cleaning
−
continued
Summary of Contents for FSH-2-PH
Page 4: ......
Page 14: ...4 Introduction FSH 2 PH ...
Page 36: ...26 Overview FSH 2 PH ...
Page 45: ...35 Operation FSH 2 PH NOTES ...
Page 53: ...43 Cleaning Maintenance FSH 2 PH ...
Page 56: ...46 Troubleshooting FSH 2 PH ...
Page 58: ...48 Parts List FSH 2 PH 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Page 64: ...54 Parts List FSH 2 PH Notes ...
Page 65: ......