34
Operation
FSH-2-PH
4.04
E.A.C. Filter Cell Cleaning Timer Operation
The hood is equipped with a
Filter Cell Cleaning Timer
. This feature is intended to help users maintain a proper
cleaning routine for the sustainable
E.A.C. Collector Cell
. Timely cleaning is essential to ensure that the cleaning
system continues to effectively remove grease
laden cooking vapor particulate from the recirculated air.
After a preset period of time expires, the timer signals that it is time to clean the collector cell
(or exchange it with a
clean standby cell, if available)
. If action is not taken within the alloted time, a timeout error alarm occurs and
power to the fryer is
disabled
and remains locked
out until filter maintenance is performed. After necessary
maintenance is performed, the timer automatically resets, a fresh countdown begins and normal operation is
restored.
Should error/alarm occur during a peak demand period or while cooking is in progress, a
SNOOZE
feature is
provided to temporarily postpone shutdown and continue operation for a short period of time.
Timer indicators and
[SNOOZE]
control button are located on the hood control box panel.
①
CHANGE SOON
The amber indicator turns ON when timer enters
[WARNING]
mode. If the
collector cell is cleaned
(or exchanged)
within the next
24 hours
, timer
automatically resets and begins a new countdown. Normal operation will
continue without interruption.
②
CHANGE NOW
The red indicator turns ON when timer enters
[TIMEOUT]
error mode, signaling
that allowed time between cleanings has expired. An audible alarm sounds,
and fryer power is
disabled
. Power is
locked out
until cleaning
(or exchange)
is
completed. The hood
[POWER]
and
[FRYER POWER]
lights will turn OFF.
Placing
Power Switch
in the
[OFF]
position silences the alarm. Hood cannot be
restarted unless the timer is reset by cleaning the cell.
Timer Operation:
1
2
NOTE: Does not apply to unit with HEPA
Filter.
③
SNOOZE Button
In the event that
[TIMEOUT]
occurs during a period of high customer demand
or while a cooking cycle is in progress, the
SNOOZE
feature may be used to
exit
[TIMEOUT]
mode. Pressing the
[SNOOZE]
button temporarily returns
timer to
[WARNING]
mode for a period of
two (2) hours,
allowing continued
operation.
Only
two (2)
snooze periods are available. When a second is used, the
[CHANGE SOON]
light flashes to indicate this is the last snooze period. After
second period expires, fryer is once again locked
out until the E.A.C. cell is
cleaned
(or exchanged)
.
NOTE: [SNOOZE] Button is only active after the timer enters [TIMEOUT] mode
and the red [CHANGE NOW] light is ON.
3
Summary of Contents for FSH-2-PH
Page 4: ......
Page 14: ...4 Introduction FSH 2 PH ...
Page 36: ...26 Overview FSH 2 PH ...
Page 45: ...35 Operation FSH 2 PH NOTES ...
Page 53: ...43 Cleaning Maintenance FSH 2 PH ...
Page 56: ...46 Troubleshooting FSH 2 PH ...
Page 58: ...48 Parts List FSH 2 PH 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Page 64: ...54 Parts List FSH 2 PH Notes ...
Page 65: ......