MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 9
Installation
Modifying Right Options Door On Wide Frame Units
For all narrow frame units, or wide frame units without stop or call buttons or door alarm
switches, proceed to “Installing Cables” on page 13. For wide or narrow frame units without
stop or call units but with door alarm, proceed to “Re-installing Door Alarm Switches” on
page 12. For wide frame units with stop or call button previously installed on right options
door, do the following to relocate hardware to new TRIND Multi 1 options door.
1
Remove all hardware from new right options door according to the following steps and save
all parts for reassembly.
• Remove two screws (1) mounting sheet metal antenna shield (2) on rear of door. Save
shield and screws for reassembly.
Note: Screw (G) fastening grounding wire on side of sheet metal shield does not need to be
removed.
• Disconnect cable R20718-G1 from light/microreader printed circuit board T20545-G1 (3)
by disconnecting J191 on cable from P191 on board.
• Remove two standoff-screws (4) holding light/microreader board (3), and remove board.
Save for reassembly.
• Remove two screws (5) and carefully pry antenna board T20551-G1 (6) off four standoffs
(7) on door and save for reassembly.
S0001732
1
2
3
4
5
6
7
G