background image

MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99

Page 9

Installation

Modifying Right Options Door On Wide Frame Units

For all narrow frame units, or wide frame units without stop or call buttons or door alarm 
switches, proceed to “Installing Cables” on page 13. For wide or narrow frame units without 
stop or call units but with door alarm, proceed to “Re-installing Door Alarm Switches” on 
page 12. For wide frame units with stop or call button previously installed on right options 
door, do the following to relocate hardware to new TRIND Multi 1 options door.

1

Remove all hardware from new right options door according to the following steps and save 
all parts for reassembly.

• Remove two screws (1) mounting sheet metal antenna shield (2) on rear of door. Save 

shield and screws for reassembly.

Note: Screw (G) fastening grounding wire on side of sheet metal shield does not need to be 

removed.

• Disconnect cable R20718-G1 from light/microreader printed circuit board T20545-G1 (3) 

by disconnecting J191 on cable from P191 on board.

• Remove two standoff-screws (4) holding light/microreader board (3), and remove board. 

Save for reassembly.

• Remove two screws (5) and carefully pry antenna board T20551-G1 (6) off four standoffs 

(7) on door and save for reassembly.

S0001732

1

2

3

4

5

6

7

G

Summary of Contents for TRIND MULTI 1 C00012-001-NF-D

Page 1: ...nce with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate this equipment Required R...

Page 2: ...ropyl alcohol part END 1082 needle nose pliers nut driver 1 4 3 8 pocket knife Q12534 CRIND diagnostic card ratchet set standard screwdrivers flat and Phillips head static guard wrist strap The following additional tools are required if kit is to be installed on wide frame units with call or stop button on existing right options door center punch deburring tool or round file hand drill battery ele...

Page 3: ...oup Q13781 01 For components see table Q13781 01 Cable Group on page 3 cable tie Q10178 02 8 8 card cage assembly T20538 G1 1 1 door assembly right options clear with TRIND T20537 G1 2 1 graphics right option door T50148 G1 see note see note grommet strip solid Q10315 06 583 ft 583 ft jump jack Q11011 01 10 10 label plate FCC N23936 01 1 1 manual graphics installation instructions MDE 2620 1 1 man...

Page 4: ... WF D Kit Quantity NF S Kit cable clamp gray Q13558 04 12 12 cable group Q13781 01 For components see table Q13781 01 Cable Group on page 3 cable tie Q10178 02 8 8 card cage assembly T20538 G1 1 1 door assembly right options clear with TRIND T20539 G1 2 1 graphics right option door T50148 G1 see note see note grommet strip solid Q10315 06 583 ft 583 ft jump jack Q11011 01 10 10 label plate FCC N23...

Page 5: ...azards Safety Symbols The following safety symbols are used throughout this manual to alert you to personal safety hazards and precautions Explosive Flammable Electrical hazard Use safety barricades No people in area No vehicles in area Use emergency power disconnect No open flames No smoking No power tools Wear eye protection Read all related manuals Clean up spills Turn power off WARNING The haz...

Page 6: ...ower to unit unit lights and STPs Use system circuit breakers Multiple disconnects may be required Isolate each pump at distribution box Refer to MDE 2531 Pump and Dispenser Start up and Service for OSHA lock out tag out procedures When system battery is present turn off system battery by pressing CLEAR then ENTER on manager keypad WARNING Dangerous Environment Failure to install this equipment in...

Page 7: ...ssure be turned off and the device breaker valve etc locked or labeled with a warning tag Read OSHA Standard 29 CFR 1910 147 Control of Hazardous Energy Sources Lock Out Tag Out Station employees and service contractors need to understand and comply with this program completely to ensure safety while the equipment is down Tag Out and Lock Out Procedure Use plastic warning tags with signature date ...

Page 8: ...uctions 3 Disconnect and remove existing hardware according to the following For wide frame units disconnect any cables and remove any call or stop buttons or door alarm switch hardware from existing right options door Save all removed hardware for reassembly For narrow frame units disconnect cables to PPU and main display 4 Remove door mounting pin and right options door 5 If unit has Cash Accept...

Page 9: ...dware to new TRIND Multi 1 options door 1 Remove all hardware from new right options door according to the following steps and save all parts for reassembly Remove two screws 1 mounting sheet metal antenna shield 2 on rear of door Save shield and screws for reassembly Note Screw G fastening grounding wire on side of sheet metal shield does not need to be removed Disconnect cable R20718 G1 from lig...

Page 10: ...punch and hammer to mark placement of pump stop or call button hole on new right options door by measuring from door edges as shown below 3 Away from fuel island drill a 7 8 inch diameter hole in location illustrated above 4 Remove any burrs around hole with deburring tool or rounded file S0001734 1 9 16 3 3 16 ...

Page 11: ...e to secure push button and base assembly to door Note Do not overtighten screws 5 Attach contact block to base with center screw if not already installed 6 If unit does not have door alarm reinstall all new right options door hardware except sheet metal shield by reversing procedures in Step 1 of Modifying Right Options Door On Wide Frame Units on page 9 and proceed to Installing Cables on page 1...

Page 12: ...ket with screw previously removed 3 Attach door alarm assembly bracket to display board with screw previously removed Note Replace the piece of fiberboard between door alarm bracket assembly and display board 4 Be sure magnet does not touch door alarm door bracket Slightly move door alarm door bracket away if necessary 5 Reinstall all new right options door TRIND hardware except sheet metal cover ...

Page 13: ... out of 2 3 4 round hole from bottom and install piece of strip grommet Q10315 06 B around perimeter of hole 3 Feed three prong end of power cable R20580 G2 J250 end of R20437 G01 ribbon cable and multiple connector ends of cables R20665 G1 and R20665 G2 up through hole and lay cable ends toward A side 4 Reinstall printer cable and retainer disconnected and removed in step 2 2 3 4 printer cable ho...

Page 14: ...its both screws will pass through holes in printer shelf For older units holes will not align with holes in shelf Remove both screws and save 4 Position rear of card cage on edge of cabinet shelf for easy cable connection Note Do not secure card cage at this time Connecting cables and setting jump jacks are easier if card cage can be manipulated by installer 5 Connect three prong female end of pow...

Page 15: ...s on Gateway Board T20128 A Side JP6 JP7 JP8 JP9 JP10 Address on Gateway Board T20128 B Side JP14 JP15 JP16 JP17 JP18 1 IN OUT OUT OUT OUT 2 OUT IN OUT OUT OUT 3 IN IN OUT OUT OUT 4 OUT OUT IN OUT OUT 5 IN OUT IN OUT OUT 6 OUT IN IN OUT OUT 7 IN IN IN OUT OUT 8 OUT OUT OUT IN OUT 9 IN OUT OUT IN OUT 10 OUT IN OUT IN OUT 11 IN IN OUT IN OUT 12 OUT OUT IN IN OUT 13 IN OUT IN IN OUT 14 OUT IN IN IN O...

Page 16: ...urn card cage sideways to unit feed top and rear of card cage up and into shelf Note Front of card cage will face B side 3 Position card cage so that tab fits over latch cutout for main door latch securing card cage to shelf divider If two screws on card cage pass through shelf secure from underside of shelf with two nuts provided in kit If screws were removed secure card cage from underside of sh...

Page 17: ...wires to contact block Route cables to Right Option Doors Note Cable R20665 G1 to A side is shorter than B side cable R20665 G2 1 Route A side cable R20665 G1 through cable clamp inside door and secure along door with clamps provided with kit 2 Route B side cable through clamps above CRIND tray to cable clamp inside door and secure along door with clamps provided with kit Note When routing from ca...

Page 18: ...0 on ribbon cable R20437 G01 to P250 on Gateway board on top of card cage From A side of unit make the following connections 1 On ribbon cable R20437 G01 connect J258A to P258 on A side CRIND Logic Board Note A side of split cable R20437 G01 has red wire 2 On ribbon cable R20437 G01 connect J258B to P258 on B side CRIND Logic Board Connect R20580 G2 power cable according to the following Note Conn...

Page 19: ...Units must have current Z 180 CRIND logic board Install the CRIND Bios TRIND software K93744 01 one per logic board on the T17764 XX CRIND logic board s according to the following steps Note A properly grounded electrostatic discharge wrist strap must be worn during this procedure U7 Chip orientation notch T17764 XX CRIND logic board G3 shown JP1 16 ...

Page 20: ...ard T17764 XX using a grounded chip removal tool 2 Install TRIND BIOS K93744 01 one per logic board at position U7 orienting notch on chip with indication mark on board as shown 3 Install jump jack on JP 16 for each side of unit Note Jumper on JP 16 informs the CRIND that a TRIND system is present 4 Restore CRIND tray to operating position Chip removal tool Grounding strap ...

Page 21: ...ller Follow these steps 1 From A side of unit locate dip switches on power supply board PCB T20314 G1 in card cage 2 Using switches 2 3 4 and 5 address each dispenser according to the following table Note Switch one in down position is standalone mode selected used for service only Setting Baud Rate For major oil company MOC TRIND installations there is no requirement to set or change baud rate Sw...

Page 22: ...Start the CRIND Refer to CRIND Service Manual MDE 2562 Note Cold Start is required if TRIND equipment is installed or changed 4 Present test tag at option door from a distance of 6 or less Light board should light and flash sequentially and emit one beep Screen prompt should appear as shown Note If light does not function properly check to see if opposite side of unit was activated indicating a cr...

Page 23: ...e and secure option and maindoor 2 Install graphics Refer to MDE 2620 Graphics Installation for The Advantage Series 3 Peel backing paper off FCC label pate provided in kit 4 Affix FCC label plate to inside frame sheathing on column under existing FCC label 5 Restore power to unit Refer to Pump and Dispenser Service Manual MDE 2531 ...

Page 24: ...0 R20437 G01 R20524 G3 R20665 G1 R20665 G2 TO P601 P708 MAIN POWER SUPPLY ASSY TI RFID TRANSFORMER SUBASSY R20719 G1 R20724 G1 R20524 G2 TI GATEWAY P C B ASSEMBLY T20128 G2 POWER SUPPLY P C B ASSEMBLY T20314 G1 LIGHT MICROREADER P C B ASSEMBLY T20545 G1 J601 J708 P601 P708 TO J601 J708 SYSTEM CABLE T19612 TO J601 SYSTEM CABLE W02468 TO P601 MAIN POWER SUPPLY ASSY TO CRIND LOGIC SEE T19503 3 P177 J...

Page 25: ...22 G9 REFLECTOR ASSY 0 6 INCH T17622 G9 REFLECTOR ASSY 0 6 INCH T17622 G9 P O W03715 G2 P O T19793 G3 2 B A C D 4 3 2 1 A B C D 1 2 3 4 CK APP TR FRACTIONS ANGLES REVISIONS SYM DESCRIPTION DR SCALE SH NO EAN NO SYM NO FINAL PROTECTIVE FINISH MATERIAL UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES ON DECIMALS 2 PLACE 3 PLACE NEXT ASSY USED ON APPLICATION GILBARCO CONFIDENTIAL GILBAR...

Page 26: ...Cable Block Diagrams 1999 Gilbarco Inc 7300 West Friendly Avenue Post Office Box 22087 Greensboro North Carolina 27420 Phone 336 547 5000 http www gilbarco com MDE 3801 10 99 Printed in the U S A ...

Reviews: