Installation
Installing Right Option Door
Mount New Right Options Door
Install new right options door according to the following steps.
1
If sheet metal shield has not been previously removed, using 1/4’’ nut driver, remove sheet
metal shield from back of door. Refer to illustration in “Modifying Right Options Door On
Wide Frame Units” on page 9 for detail. Save cover and hardware.
2
Remove key taped to inside of new right options door and save.
3
Position new right options door and install with pin removed with old door and saved.
Note: If unit had stop or call button transferred from old door to new TRIND door, reconnect
stop or call button wires to contact block.
Route cables to Right Option Doors
Note: Cable R20665-G1 to A side is shorter than B side cable R20665-G2
1
Route A side cable R20665-G1 through cable clamp inside door and secure along door with
clamps provided with kit.
2
Route B side cable through clamps above CRIND tray to cable clamp inside door, and secure
along door with clamps provided with kit.
Note: When routing from cabinet to main door, allow sufficient slack in cables to allow main
door to open and close without pulling or crimping cables. Also check that cable is not
crimped when door is closed.
3
Route cables around board as shown for both wide and narrow frame units, securing cable to
board with tie-wrap.
4
Connect J182 on each cable to P182 on PCB assembly on option door.
5
Reinstall sheet metal cover on door, being careful to avoid crimping cables.
Cable clamps provided with kit
R20665-XX cable
Cable clamp inside door
tie-wrap
J182