Installation
Page 8
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Installation
Preparing for Installation
1
Before proceeding read and follow all safety instructions and procedures.
2
Open main access doors. Refer to MDE-2531, Pump and Dispenser Start-Up/Service Manual
for access instructions.
3
Disconnect and remove existing hardware according to the following:
• For wide frame units disconnect any cables and remove any call or stop buttons, or door
alarm switch hardware from existing right options door. Save all removed hardware for
reassembly.
• For narrow frame units disconnect cables to PPU and main display.
4
Remove door mounting pin and right options door.
5
If unit has Cash Acceptor, remove door alarm and all hardware from old door and save.
6
Dispose of door. Save pin for reassembly.
S0001719
Pin