![GILBARCO VEEDER-ROOT FlexPay IV Insite360 Encore Programming And Service Manual Download Page 85](http://html1.mh-extra.com/html/gilbarco-veeder-root/flexpay-iv-insite360-encore/flexpay-iv-insite360-encore_programming-and-service-manual_2227135085.webp)
Omnia Maintenance Through USB
Omnia PCB
MDE-5369E FlexPay™ IV (with Omnia) Programming and Service Manual · April 2020 Page 5-55
Installing Packages
To install packages, proceed as follows:
1
Open
OmniaOp.json
file with a text editor (e.g. +).
2
Enter the time after which Omnia must reboot as shown in the following figure:
Figure 5-80: Entering Time After which Omnia Reboots
“Time” field in MINUTES. It setups the time after which Omnia reboots.
Min value is 3 minutes.
Note: The minimum value to be entered is 3 minutes.
3
Save the file.
4
Go to
gvr\omnia\pkgs
and load the packages to be uploaded (debians, archives).
5
Plug USB drive into Omnia board. Depending on the success or failure of the operations,
LEDs start glowing as follows:
• LED D32 goes Solid RED and LED D31 starts blinking slow.
• LED D31 goes Solid GREEN, indicating that the operation is successfully completed.
• LED D31 will start blinking fast, indicating that the operation failed.
• LED D28 starts blinking slow and becomes Solid GREEN when the command is sent
successfully (almost immediately).
• LED D28 will start blinking fast, indicating that the operation failed.
If both operations are successful, LED D32 goes OFF. If one or more of the operations fails,
LED D32 will start blinking together with the LED related to the failed operation.
6
Remove the USB drive.
7
Omnia will reboot in the time specified in step
.