8003 Precision Scalar Analyzer
2-34
Manual 20791, Rev. C, June 2001
[
FREQ LBL ON/OFF]
Menu F3-17:
Toggles the frequency labels to be displayed or removed from the graph display as
indicated. The frequency labels include the start, stop, cursor and cursor
∆
frequency labels
which are shown at the bottom of the graphic display. This can be specified at any time. How-
ever, if the routine is in the data readout display mode, any changes will not be apparent until
the graph display mode is entered.
[
TITLE ON/OFF]
Menu F3-17:
Toggles the main display title to be displayed or not displayed as indicated. See
also the Title softkey description below regarding definition of the title.
[
CH TTL ON/OFF]
Menu F3-17:
Toggles the title of the entry channel to be displayed or not displayed as indi-
cated.
[TITLE]
Menu F3-12:
Edit the main display title. The [
CHANNEL TITLE
] softkey changes the entry
channel title. When either softkey is pressed, the indicated title will be turned on if it is off and
a cursor bar will flash immediately below the character space in the title to be filled when
another character is chosen. The softkey menu will change to F3-18.
[
ALPHA/CURS POS]
Menu F3-18:
Selects whether to activate the alpha character softkey labels in order to create
or modify a title, or to access control over the cursor positioning.
[
UNDO/ERR TTL]
Menu F3-18:
Erases a complete title or undo (restore) the title if erased by mistake. Note that
it is only possible to undo the title if no new letters have been entered after selecting
ERR TTL.
The alpha softkeys have labels of six characters each for selection of characters for the title
being edited. A cursor in the form of a small square box will be over one of the characters in
each alpha softkey label. The cursor will be in the same position in each of the alpha softkey
labels. For example if the cursor is on A, it will also be on G, M, S and Y.
The cursor can be moved with the spin knob. Moving the wheel in a clockwise direction will
cause the cursor to also move in a clockwise direction. For example, if the cursor is on the letter
C and the spin knob is turned in a clockwise direction, the cursor will move to the letter F.
Similarly, moving the spin knob in a counterclockwise direction will cause the cursor to also
move in a counterclockwise direction. For example, if the cursor is on the letter A and the spin
knob is turned in a counterclockwise direction, the cursor will move to the letter D.
If an alpha softkey is pressed, the associated character in the cursor box is inserted in the next
character position in the title. Numbers can be inserted in the same way through the numeric
keypad of the instrument. The point, hyphen, forward slash, and plus symbols can be inserted
where required using the fifth alpha key, and a space can be placed at any point after the last
character position using the bottom softkey of the menu. The Backspace (BK SP) key will also
be active and, if pressed, will erase the last character defined in the title.
Summary of Contents for 8003
Page 3: ......
Page 14: ...8003 Precision Scalar Analyzer x Manual 20791 Rev C June 2001 ...
Page 16: ...8003 Precision Scalar Analyzer xii Manual 20791 Rev C June 2001 ...
Page 18: ...8003 Precision Scalar Analyzer xiv Manual 20791 Rev C June 2001 ...
Page 20: ...8003 Precision Scalar Analyzer xvi Manual 20791 Rev C June 2001 ...
Page 36: ...8003 Precision Scalar Analyzer 1 16 Manual 20791 Rev C June 2001 ...
Page 142: ...8003 Precision Scalar Analyzer 2 106 Manual 20791 Rev C June 2001 ...
Page 232: ...8003 Precision Scalar Analyzer 4 18 Manual 20791 Rev C June 2001 ...
Page 252: ...8003 Precision Scalar Analyzer B 16 Manual 20791 Rev C June 2001 ...
Page 258: ...8003 Precision Scalar Analyzers Index 6 Manual 20791 Rev C June 2001 ...