![Giga-tronics 2508A Operation Manual Download Page 35](http://html1.mh-extra.com/html/giga-tronics/2508a/2508a_operation-manual_2222729035.webp)
2500A Menus
2500A Series Operation Manual, 34172 Revision C, March 2008
repeats. The sweep occurs in a set number of equal increments, as determined by the Resolution setting.
The output power is held at the same level during a frequency sweep.
NOTE:
As soon as theStep Swep menu is chosen, the instrument calculates the ramp, then begins
sweeping the output frequency. The ramp is recalculated whenever a parameter is changed.
During calculations, the following message is shown at the bottom of the display:
Preparing sweeping data...
When the calculations are complete and the output is actively sweeping, the following mes-
sage is shown:
Step sweeping
Figure 2-10 shows the Step Sweep menu:
Figure 2-10: Ramp Freq Menu with Interactive Softkeys
The following explains each item in the Ramp Freq menu:
Start Frequency.
This menu item displays and allows you to modify the ramp start frequency. This is
the frequency that will be used as the starting frequency of the frequency sweep. Note that the start fre-
quency must be less than the stop frequency. If the start frequency is set higher than the stop frequency,
the stop frequency is automatically adjusted to the same value.
Stop Frequency.
This menu item displays and allows you to modify the ramp stop frequency. This is the
frequency that will be used as the ending frequency of the frequency sweep. Note that the stop frequency
must be greater than the start frequency. If it is set lower than the start frequency, the start frequency is
automatically adjusted to the same value.
Power.
This menu item displays and allows you to modify the output power level to be used during the
frequency sweep. The range of the power level depends on the following configuration and settings of
the instrument:
Step Time.
This menu item allows you to view and modify the step time. This is the amount of time that
a single frequency step is executed. When the last frequency in the step sweep is executed and com-
RAMP FREQ
10.00 MHz
20.0 GHz
0.00 dBm
1.00 Sec
Start Frequency
Stop Frequency
Sweep Time
Power
401
Resolution
Ramp Power