The manual unlocking device is situated on the support bracket of the gate and allows unlocking the gate both from 
the inside and the outside of the property.

To manually open the gate, operate as follows:

[

]

• Uncover the lock sliding off the protective cap as shown in 

22

.

[

]

• Insert the unlocking key in the lock 

22

 and turn it.

• Pull the lever towards you and manually move the leaf.

• Turn the key for an additional 180° and remove it from the lock.

WARNING: it is essential that the key is turned for at least 180° during the manual operation.

To restore normal operation, act as follows

[

]

• Strip the lock sliding the protection as in 

22

.

[

]

• Insert the unlocking key in the lock 

22

 and turn it for 180°.

• Manually move the leaf until the lock couples on the locking bracket.

• Take the key back to its original position and remove it.

• Close the protective lock sliding cap.

:

It is recommended to use an electric lock for leaves larger than 2.5 m and in any case for blind or flush panel doors

À

ELECTRIC LOCK

Á

ELECTRIC LOCK FASTENING PLATE

Â

LATCH COUPLING

Ã

ND-STOP FOR LATCH COUPLING 

Ä

LATCH

Å

THROUGH CYLINDER (ON REQUEST)

Æ

GATE

.

Power the system and run a complete opening and closing cycle checking that

• The safety devices function properly;

• The gate moves smoothly;

• The solidity of the foundation plate;

• The gate assembly conforms to 

EN 12453

 and 

EN 12445

.

For further details and information on the reference standards, visit our website: 

www.gibidi.com

:

RESTORING NORMAL OPERATION

[

] [

]

FITTING THE ELECTRIC LOCK

24

 - 

25

 

FINAL TESTING 

GROUND

23

Summary of Contents for GROUND 610

Page 1: ...NL I E Operatore interrato elettromeccanico ISTRUZIONI PER L INSTALLAZIONE LEVERISMO AMBIDESTRO Electromechanical underground operator INSTRUCTIONS FOR INSTALLATION AMBIDEXTROUS LEVER GROUND GROUND 61...

Page 2: ...10 230Vac DESCRIZIONE CAVI CABLES DETAILS 1 2 Rosso Red Nero Black Negativo Negative Positivo Positive GROUND 624 24Vdc GROUND 610 230Vac GROUND 624 24Vdc 2 5 x 4 1 3 8 4 7 3 8 5 9 1 6 cavo marrone br...

Page 3: ...GROUND 3 2a 3 4 2b PULL 60 mm 180 mm 436 mm 353 mm 414 mm 343 mm 72 mm 72 mm 180 mm 180 mm 72 mm 60 mm...

Page 4: ...GROUND 4 9 7 8 6 5 72 mm 35 mm 200 mm 400 mm 500 mm 6 5 3 4 2 1...

Page 5: ...GROUND 11 13 14 10 12 min 10 mm C 250 mm min 40 mm C PULL 5...

Page 6: ...CAVI CABLES DETAILS Blu Blue 1 2 3 4 Viola Purple Rosso Red Marrone Brown Negativo Negative Positivo Positive Apre Open Chiude Close 29 28 27 26 25 24 23 22 21 20 19 18 COSTA PHOTO 1 FCC M1 COM RISER...

Page 7: ...1 2 3 4 Viola Purple Rosso Red Marrone Brown Negativo Negative Positivo Positive Apre Open Chiude Close 31 32 30 29 28 27 26 25 24 23 22 21 20 COSTA COSTA PHOTO 1 FCC M1 COM RISERVA PHOTO 2 FCC M2 FCA...

Page 8: ...GROUND 8 20 21...

Page 9: ...6 5 3 4 7 3 5 1 2 4 7 4 3 6 5 1 2 GROUND 22 24 25 23 9...

Page 10: ...ata come professione e nel rispetto delle norme vigenti Lamanutenzionedeveessereeseguitadapersonalequalificato Prima di eseguire qualsiasi operazione di pulizia o di manutenzione scollegare l apparecc...

Page 11: ...O per una lunghez za cavo massimo 6 m oltre necessario aumentare la sezione del cavo Apparecchiaturacavo3x1 5mm rasmettitorefotocellulacavo2x0 5mm Antenna cavocoassialeschermatoRG58 Scatoladiderivazio...

Page 12: ...allagamenti Se il cancello non di nuova installazione controllare lo stato di usura di tutti i componenti sistemare o sostituire le partidifettoseousuratee senecessario effettuaregliopportuniintervent...

Page 13: ...1 Montareilgruppolevesulpernodellacassetta 10 MODO1 2 ProcurarsiunprofilatoadUdidimensioniindicatein 11 3 SaldarelastaffaaUsulbracciodisostegnodell operatore 12 4 Alloggiareilcancellonellastaffaguidae...

Page 14: ...guireleproceduredelcapitolosuccessivoprimadicontinuare 21 6 Fissarelalevainseritaalpunto3all alberodelriduttoreconl appositospinotto MONTAGGIO DELL OPERATORE 1 Montareleduevitiatestacilindrica e 18 di...

Page 15: ...i180 Azionaremanualmentel antafinoall agganciodellaserraturasullastaffadibloccaggio Riportarelachiavenellaposizioneinizialeedestrarla Richiudereiltapposcorrevolediprotezionedellaserratura L elettroser...

Page 16: ...a regolazione della sicurezza elettronica antischiacciamento e l efficienza dei sistemadisbloccochepermetteilfunzionamentomanuale vediparagraforelativo I dispositivi di sicurezza installati sull impia...

Page 17: ...INTERRATI ELETTROMECCANICI GROUND 610 624 sono conformi alle seguenti Direttive CEE Direttiva LVD 2006 95 CE e successive modifiche Direttiva EMC 2004 108 CE e successive modifiche e che sono state ap...

Page 18: ...knowledgeandprofessionalpracticeincompliancewiththeregulationsinforcearerequired Maintenancemustbecarriedoutbyqualifiedpersonnel Before carrying out any cleaning or maintenance operation disconnect th...

Page 19: ...closing yellow green ground Underground motor GROUND624 2 x 1 5 mm cable power supply RED BLACK for a cable length of 6 m max over it s necessary increase the cable section Controlunitcable Photocell...

Page 20: ...he gate structure is sufficiently robust In any case check that the gate weight and dimensions fall withintheoperatinglimitsoftheoperator Maximumleaflength 2 5m maximumweight 600kg 3 5m maximumweight...

Page 21: ...1 Fittheleverunittotheboxpin 10 MODO1 2 ProcureaU bracketwiththedimensionsindicatedin 11 3 WeldtheU bracketontheoperatorsupportarm 12 4 Positionthegateintheguidebracketandhingeitintheupperpart 5 Chec...

Page 22: ...s refertonextparagraphbeforegoingon 21 6 Fastentheleverfitatpoint3tothereductiongearshaftwiththesuitableplug OPERATOR INSTALLATION 1 Fitthetwocheese headedscrews e 18 directlyontheoperatorbody 18 2 Fa...

Page 23: ...ingkeyinthelock 22 andturnitfor180 Manuallymovetheleafuntilthelockcouplesonthelockingbracket Takethekeybacktoitsoriginalpositionandremoveit Closetheprotectivelockslidingcap Itisrecommendedtouseanelect...

Page 24: ...t of the electronic anti crushing safety device and the efficiency of the unlocking deviceformanualoperation seetherelevantparagraph The safety devices installed on the system must be checked every si...

Page 25: ...NICAL GEARMOTORS GROUND 610 624 are in conformity with the following CEE Directives LVD Directive 2006 95 CE and subsequent amendments EMC Directive 2004 108 CE and subsequent amendments and that the...

Page 26: ...gueur Lamaintenancedoit treeffectu eparunpersonnelqualifi Avant d effectuer toute op ration de nettoyage ou de maintenance il faut d brancher l appareil des r seaux d alimentation lectrique Ce produit...

Page 27: ...OUND624 alimentation c ble ROUGE NOIR pour une longueur c ble de 6 m max au del c est n cessaire augmenter la section du c ble Appareilc ble Emetteurphotocellulec ble Antenne c blecoaxialblind RG58 Bo...

Page 28: ...ttements Contr lespr liminaires Ilfautcontr lerquelastructureduportailestassezsolide Danstouslescas ilfautcontr lerqueleportailalepoids etlesdimensionsquisontdansleslimitesd utilisationdel op rateur L...

Page 29: ...aisson 10 MODE1 2 SeprocurerunprofilenUayantlesdimensionsindiqu esen 11 3 Souderl trierenUsurlebrasdesupportdel op rateur 12 4 Logerleportaildansl trierguideetlefixerauxcharni reparlapartiesup rieuree...

Page 30: ...phesuivantavantdecontinuer 21 6 Fixerlelevierintroduiteaupoint3 l arbredur ducteuraveclegoujonappropri MONTAGE DE L OPERATEUR 1 Monterlesdeuxvis t tecylindrique e 18 directementsurlecorpsdel op rateur...

Page 31: ...80 Actionnermanuellementlevantailjusqu l accrochagedelaserruresurl trierdeblocage Reporterlacl danslapositioninitialeetl extraire Refermerlebouchoncoulissantdeprotectiondelaserrure L lectroserrureestc...

Page 32: ...ue contre l crasement et l efficacit du syst me ded blocagequipermetlefonctionnementmanuel voirleparagraphecorrespondant Lesdispositifsdes curit install ssurl installationdoivent trecontr l stouslessi...

Page 33: ...TROM CANIQUES GROUND 610 624 sont en conformit avec les exigences des Directives CEE Directive LVD 2006 95 CE et ses modifications Directive EMC 2004 108 CE et ses modifications et que les normes harm...

Page 34: ...cimientot cnico ejercidocomoprofesi nyrespetandolasnormasvigentes Elmantenimientodebeserrealizadoporpersonalcapacitado Antesderealizarcualquieroperaci ndelimpiezaomantenimiento desconecteelequipodelar...

Page 35: ...do GROUND624 alimentaci n del cable ROJO NEGRO por una longitud cable de 6 m max m s all es necesario augmentar la secci n del cable Equipocable Transmisorfotoc lulacable ntena cablecoaxialblindado Ca...

Page 36: ...nares Controle que la estructura de la puerta sea suficientemente robusta En todo caso compruebe que el peso y las dimensionesdelapuertarespetenlosl mitesdeusodeloperador Longitudm ximadelahoja 2 5m p...

Page 37: ...efectuar el montaje 1 Montarelgrupodepalancasenelpernodelacaja 10 MODO1 2 ProcurarseunperfilenUdeltama oindicadoen 11 3 SoldarelestriboenUenelbrazodesoportedeloperador 12 4 Colocarlacancelaenelestrib...

Page 38: ...consultarelparrafosiguienteantesdecontinuar 21 6 Fijarlapalancaintroducidaalpunto3enelejedelreductorconelpernoapropriado MONTAJE DEL OPERADOR 1 Montarlosdostornillosdecabezacil ndrica e 18 directament...

Page 39: ...ygirarlade180 Accionemanualmentelahojahastaengancharlacerraduraenelestribodebloqueo Llevarlallaveenlaposici ninicialysacarla Vuelvaacerrareltap ndeslizantedeprotecci ndelacerradura Laelectrocerradura...

Page 40: ...electr nico de seguridad antiaplastamiento est bien regulado y que el sistemadedesbloqueoquepermiteelfuncionamientomanualest eficiente v aseelp rrafocorrespondiente Losdispositivosdeseguridadinstalad...

Page 41: ...TORREDUCTORES ELECTROMEC NICOS GROUND 610 624 cumplen las siguientes Directiva CEE Directiva LVD 2006 95 CE y modificaciones sucesivas Directiva EMC 2004 108 CE y modificaciones sucesivas y que se han...

Page 42: ...techniek is dus vereist De installatie moet uitgevoerd worden door vakmensen en de geldigewetgevingdientgerespecteerdteworden Hetonderhoudmoetuitgevoerdwordendoorvakkundigpersoneel Voordat reinigings...

Page 43: ...GROUND 43 NL...

Page 44: ...urvanhethekstevigenstargenoegis Controleerinelkgevalofhetgewichtende afmetingenvanhethekbinnendegebruiksgrenzenvandeaandrijverliggen Maximumlengtevandevleugel 2 5m Maximumgewicht 600kg 3 5m Maximumgew...

Page 45: ...gd is alvorens de montage uit te voeren 1 Monteerdegroephendelsopdeasvandedoos 10 OPLOSSING1 2 ZoogvooreenU profielmetdematenaangegevenin 11 3 LasdeU beugelopdesteunarmvandeaandrijver 12 4 Brenghethek...

Page 46: ...elektrischeeindschakelaarsgebruikt zievolgendeparagraafalvorensverdertegaan 21 6 Bevestigdehendeldiepastoppunt3vandereductorasmetdegepasteplug MONTAGE VAN DE AANDRIJVER 1 Monteerdetweecilinderkopschro...

Page 47: ...vleugelmetdehandtotdathetslotopdegrendelbeugelingrijpt Haaldeontgrendelingssleutelterugnaarzijnoorspronkelijkepositieenverwijderhem Sluitweerdeschuifbeschermingvanhetslot Hetelektroslotisverplichtvoor...

Page 48: ...handbedieningzorgtgoedwerkt ziebetreffendeparagraaf De op de installatie aangebrachte veiligheidsvoorzieningen moeten elk half jaar gecontroleerd worden Gi Bi Di Srl behoudt zich het recht voor om zo...

Page 49: ...n ELEKTRONISCHE REDUCTIEMOTOREN GROUND 610 624 conform de volgende CEE richtlijnen zijn Richtlijn LVD 2006 95 CE en daaropvolgende wijzigingen Richtlijn EMC 2004 108 CE en daaropvolgende wijzigingen e...

Page 50: ...GROUND 50 NOTE NOTES...

Page 51: ...GROUND 51 NOTE NOTES...

Page 52: ...DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail comm gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC8169 05 2011 Re...

Reviews: