DESRCIZIONE MENU ( A )
DESRCIZIONE MENU ( A )
18.4 - DESCRIPTION MENU ( E )
18.4 - DESCRIPTION MENU ( E )
Menu
Function
Description
Status
It allows to display the setting of terminal 24, defined with menu
C40, and the number of safety intervention, determined by the
input if set as EDGE N.C. or as EDGE 8K2.
Display (example):
The terminal 24 is set as edge NC and has intervened 99 times
(max. number).
Operation:
With ESC you come back.
With OK the interventions digit blinks.
With + or – you set to zero the interventions number.
Warning:
AT EVERY NEW SETTING OF THE INPUT THE
INTERVENTIONS NUMBER IS SET TO ZERO.
Interventions number
DISPLAY OF SETTING AND
INTERVENTION NUMBER
OF SAFETY INPUT No.1
(TERMINAL 24)
E 40
It allows to display the setting of terminal 25, defined with menu
C41, and the number of safety interventions, determined by the
input if set as EDGE N.C. or as EDGE 8K2.
Operation:
See E40
E 41
It allows to display the setting of terminal 26, defined with menu
C42, and the number of safety interventions, determined by the
input, if set as EDGE N.C. or as EDGE 8K2.
Operation:
See E40
E 42
DISPLAY OF SETTING AND
INTERVENTIONS NUMBER
OF SAFETY INPUT No.2
(TERMINAL 25)
DISPLAY OF SETTING AND
INTERVENTIONS NUMBER
OF SAFETY INPUT No.3
(TERMINAL 26)
O6 99
Terminal setting from MENU C40
Menu
Function
Description
Status
E 43
E 44
It allows to set a number of cycles (o closing) before
the request for maintenance.
The set value is always multiplied by 10.
If 0000 is set, the numbering is excluded.
When the number of cycles set is reached, the maintenance
request will be signalled by a slow blinking of 60 sec. at the
end of the manoeuvre.
WARNING: Each time you enter in menu E90 (WITH
BLINKING NUMBERS, THAT MEANS READY TO BE
MODIFIED), the counting of the cycles number is set to zero
starting from the beginning.
NUMBER OF
MAINTENANCE CYCLES
E 90
It allows to customize the PASSWORD to acceed to the
programming of the control unit, see chapter 11.
Only if you know the PASSWORD, you can acceed to the
programming.
PASSWORD
E 92
It shows the firmware version installed on the control unit.
(XX__YY)
FIRMWARE VERSION
E 94
Number of manoeuvres done.
The value displaied is increased every 10 manoeuvres.
NUMBER OF CYCLES
DONE
E 96
It allows to display the setting of terminal 27, defined with menu
C43, and the number of safety interventions, determined by the
input if set as EDGE N.C. or as EDGE 8K2.
Operation:
See E40
DISPLAY OF SETTING AND
INTERVENTIONS NUMBER
OF SAFETY INPUT No.4
(TERMINAL 27)
It allows to display the setting of terminal 28, defined with menu
C44, and the number of safety interventions, determined by the
input if set as EDGE N.C. or as EDGE 8K2.
Operation:
See E40
DISPLAY OF SETTING AND
INTERVENTIONS NUMBER
OF SAFETY INPUT No.5
(TERMINAL 28)
Number of days of control unit power supply.
This data is increased when 24 hours are past.
Possible lacks of power supply set to zero the counting of last
day.
NUMBER OF POWER
SUPPLY DAYS
E 98