46
47
SC380
SC380
UK
UK
DESRCIZIONE MENU ( A )
DESRCIZIONE MENU ( A )
18.4 - DESCRIPTION MENU ( E )
18.4 - DESCRIPTION MENU ( E )
Menu
Function
Description
Status
REL1 set as
electric lock.
Enabled for 3 seconds at the
beginning of opening and closing
2
REL1 set as
courtesy light
Enabled for 3 minutes more after motor stop
3
REL1 set as
flashing light
Synchronized blinking with LAMP 230V (fixed or intermittent)
output
4
REL1
Enabled for the complete opening and closing (excluded in
pause)
set as
fixed light
5
REL1
beginning of opening and closing
set as
electric magnet.
Turned off for 3 seconds at the
6
REL1 management
Terminals 8-9
(FREE CONTACT)
Fig. 14
E 32
REL2 set as electric lock. Enabled for 3 seconds at the
beginning of opening and closing
2
REL2 set as
Enabled for 3 minutes more after motor stop
courtesy light
3
REL2
Synchronized blinking with LAMP 230V (fixed or intermittent)
output
set as
flashing light
4
REL2
Enabled for the complete opening and closing (excluded in
pause)
set as
fixed light
5
REL2
beginning of opening and closing
set as
electric magnet.
Turned off for 3 seconds at the
6
REL2 management
Terminals 10-11
(FREE CONTACT)
Fig. 15
E 34
Menu
Function
Description
Status
It disables the reading of the motor revolutions sensor.
1
It enables the reading of motor revolutions sensor.
VERY HIGH intervention sensitivity
Operation:
After a reduction of the number of revolutions of the motor (for
example, obstacle) the sensor intervenes blocking the motion
of the gate and inverting the movement for 2 seconds to free the
obstacle.
When a new Start pulse is given, the motion starts again in the
direction of obstacle feeeing.
Disabled with DEAD MAN.
See also MENU E30.
2
MOTOR REVOLUTIONS
SENSOR (INDUCTIVE
SENSOR)
E 36
It enables the reading of the motor revolutions sensor.
HIGH intervention sensitivity
Operation:
As the previous menu
3
It enables the reading of the motor revolutions sensor.
MEDIUM intervention sensitivity
Operation:
As previous menu
4
It enables the reading of the motor revolutions sensor.
LOW intervention sensitivity
Operation:
As previous menu
5
Enables the reading of the motor revolutions sensor.
VERY LOW intervention sensitivity
Operation:
As previous menu
6
Summary of Contents for AS05800
Page 1: ...SC380 UK SC380 AS05800 AS05810 Electronic control unit INSTRUCTIONS FOR INSTALLATION ...
Page 3: ...SC380 3 UK AS05800 31 6 236 1 2 8 236 31 6 AS05810 1 2 8 DIMENSIONS 1 ...
Page 4: ...4 SC380 UK INSTALLATION 2 170 250 ...
Page 54: ...54 SC380 UK NOTES ...
Page 55: ...55 SC380 UK NOTES ...