18
19
SC380
SC380
UK
UK
1 - SPECIFICATION SHEET
Control unit
Type
Power supply
Line disconnector
N° motors
Motor power supply
Flashing light
Warning light
Electric lock
Accessories power supply
Radio receiver
Operating temperature
Protection degree
Code
Electronic control unit for the automation of one 230Vac or
380Vac motor for swinging, sliding gates or bollards.
SC380
Yes
No
1
230Vac Monophase 50/60 Hz
230 / 380Vac Three-phase 50/60 Hz
230Vac 40W max
230Vac Monophase 50/60 Hz
230 / 380Vac Three-phase 50/60 Hz
24Vdc 3W max
Managed by relay with free contact
24Vdc 8W max
Safety devices power supply
Plug-in
-20°C +60°C
IP 55
Safety devices test
Yes
Energy saving
Yes
AS05800
AS05810
2 - TECNICHAL SPECIFICATIONS AND FUNCTIONS
Red warning leds of NC contacts. There is not the safety devices led (from terminals 24 to 28). See “SIGNALLING
LED” table.
Green warning leds of NO contacts. See “SIGNALLING LED” table.
Management of 1 electric lock by a relay with free contact.
Management of 1 electric magnet by a relay with free contact.
Management of the courtesy light by a relay with free contact.
Safety test run before the opening and closing movement.
Photocell test run before the opening and closing movement.
Motion stop and inversion for 2 seconds after the intervention of the safety devices.
Additional attempts (till 5) after the intervention of safety devices to allow the restart of the motion.
Safety devices test.
Energy saving (ENERGY SAVING).
Digital programming of all functions.
Working time adjustable independently in opening and closing.
Adjustable pedestrian working time.
Adjustable pause time, differentiated for complete or pedestrian opening.
4 possible working functions (step by step, step by step with stop, condominium or automatic, dead man).
Possibility of choosing the system configuration between swinging, sliding gate and bollard.
Setting of 5 safety inputs, selectable as inputs: STOP-RESISTIVE NC-RESISTIVE 8K2-PHOTO1-PHOTO2.
Setting of:
§
Automatic closing.
§
Fast closing.
§
Pre-flashing.
§
Hammer stroke.
§
Final opening and closing stroke.
§
Courtesy light.
§
Fixed or intermittent flashing light.
§
Reserve input with 3 different operating modes.
§
Hydraulic block maintenance.
§
Electronic brake.
§
Number of cycles for scheduled maintenance.
§
Installer password.
Display of the number of cycles done and of the number of power supply days.
Possibility of powering the control unit and 230V monophase 50/60Hz or 230 / 380V three-phase 50/60Hz motor.
Main line switch (disconnector 16A )with door locking device (code AS05800).
Motor braking always active at each stop (if in sliding operator mode).
Synchronism with a different control unit allowed with simplified wiring.
Motor revolutions sensor for obstacle detection and motion inversion.
Summary of Contents for AS05800
Page 1: ...SC380 UK SC380 AS05800 AS05810 Electronic control unit INSTRUCTIONS FOR INSTALLATION ...
Page 3: ...SC380 3 UK AS05800 31 6 236 1 2 8 236 31 6 AS05810 1 2 8 DIMENSIONS 1 ...
Page 4: ...4 SC380 UK INSTALLATION 2 170 250 ...
Page 54: ...54 SC380 UK NOTES ...
Page 55: ...55 SC380 UK NOTES ...