40
41
SC380
SC380
UK
UK
DESRCIZIONE MENU ( A )
DESRCIZIONE MENU ( A )
18.2 - DESCRIPTION MENU ( C )
18.2 - DESCRIPTION MENU ( C )
Menu
Function
Description
Status
Input DISABLED.
1
Input programmed as STOP
Operation:
The STOP enabling blocks the automation and the restart of
the motion will occur only after a START/ PEDESTRIAN /OPEN
/CLOSE command.
2
programming of
SAFETY DEVICES No.4
input (terminal 27)
named SAFETY 2
C 43
3
4
5
6
Input programmed as PHOTOCELL 1
Operation:
Input active only during closing phase.
It stops the motion and inverts opening completely.
If intercepted in pause, it reloads the pause time.
If enabled, it allows the fast closing (see menu C1)
Input programmed as PHOTOCELL 2
Operation:
Input active both in opening and closing.
If intercepted, it stops the motion and keeps blocked till when it
is not freed.
At release the motion restarts always in opening.
If intercepted in pause, it reloads the pause time.
Input programmed as EDGE 8K2.
Operation:
obstacle freeing way.
OPEN/ CLOSE, the motion restarts in opening or closing
Input active both in opening and closing.
It stops the motion and inverts the movement for 2 seconds.
The gate will keep blocked waiting for a command:
START/PEDESTRIAN, the motion restarts towards the
Input programmed as EDGE N.C.
Operation:
See description of EDGE 8K2 operation
Menu
Function
Description
Status
Input DISABLED.
1
Input programmed as STOP
Operation:
STOP enabling blocks the automation and motion restart will
occur only after a START / PEDESTRIAN / OPEN / CLOSE
command.
2
programming of
SAFETY DEVICES No.5
input (terminal 28)
named STOP
C 44
3
4
5
6
Input programmed as PHOTOCELL 1
Operation:
Input active only during the closing phase.
It stops the motion and inverts opening completely.
If intercepted in pause, it reloads the pause time.
If enabled, it allows the fast closing (see menu C1)
Input programmed as PHOTOCELL 2
Operation:
Input active both in opening and closing.
If intercepted, it stops the motion and keeps it blocked till when
it is not freed.
At release the motion restarts always in opening.
If intercepted in pause, it reloads the pause time.
Input programmed as EDGE 8K2.
Operation:
obstacle freeing way.
OPEN/ CLOSE, the motion restarts in opening or closing
Input active both in opening and closing.
It stops the motion and inverts the movement for 2 seconds.
The gate will keep blocked waiting for a command:
START/PEDESTRIAN, the motion restarts towards the
Input programmed as EDGE N.C.
Operation:
See description of EDGE operation 8K2
Summary of Contents for AS05800
Page 1: ...SC380 UK SC380 AS05800 AS05810 Electronic control unit INSTRUCTIONS FOR INSTALLATION ...
Page 3: ...SC380 3 UK AS05800 31 6 236 1 2 8 236 31 6 AS05810 1 2 8 DIMENSIONS 1 ...
Page 4: ...4 SC380 UK INSTALLATION 2 170 250 ...
Page 54: ...54 SC380 UK NOTES ...
Page 55: ...55 SC380 UK NOTES ...