18 - MENU DESCRIPTION
WARNING:
The
DEFAULT
settings are in grey spaces
18.1 - DESCRIPTION MENU ( A )
Menu
Function
Description
2
A 1
TYPE OF
INSTALLATION
Status
It configures the system for swing gate.
With this configuration:
the electronic brake is automatically excluded.
It configures the system for sliding gate
With this configuration it will be automatically:
excluded the water hammer.
excluded the final stroke.
excluded the hydraulic block maintenance.
active the limit switch reading.
IMPORTANT: Menus C4, C10, C11, C13 are not visible any
more.
active the electronic brake.
3
A 3
STEP BY STEP
WITH STOP
LOGIC
2
It enables the STEP BY STEP WITH STOP Logic
Operation after a START command :
Close gate
OPEN
→
During opening
STOP
→
Open gate
CLOSE
→
During closing
STOP
→
After a STOP
invert the motion
→
Configures the installation for rising bollard using the
additional control unit BX-6M (AS07010).
With this configuration il will be automatically:
excluded the electronic brake.
excluded the water hammer.
excluded the final stroke.
disabled the limit switch reading.
WARNING:
Menus A3_5, A5_2, A5_4 C4, C10, C11, C15, C23, H10,
H11, E5, E9, E32, E34, E36 are not visible any more.
Refer to the manual of the control unit BX-6M (As07010)
and chapter 21 of this manual.
4
18.1 - DESCRIPTION MENU ( A )
Menu
Function
Description
Status
5
DEAD MAN LOGIC
It enables the DEAD MAN Logic
Operation:
OPENING
→
opens only if you keep the OPENING
button pressed.
CLOSING
→
closes only if you keep the CLOSING
button pressed.
A 3
It disables the automatic closing.
I
n pause
(open gate):
START will cause the closing.
The CLOSING button will activate the closing.
1
AUTOMATIC CLOSING
A 5
It enables:
the
total
automatic closing (See Menu H9)
the
pedestrian
automatic closing (See Menu H11)
2
It enables
only
the total automatic closing
(See Menu H9)
3
It enables
only
the pedestrian automatic closing
(See Menu H11)
4
STEP BY STEP LOGIC
3
It enables the STEP BY STEP Logic
Operation after a START command:
Close gate
OPEN
→
During opening
CLOSE
→
Open gate
CLOSE
→
During closing
OPEN
→
AUTOMATIC
CONDOMINIUM LOGIC
4
It enables the AUTOMATIC Logic
Operation after a START command:
Close gate
OPEN
→
During opening
IRRELEVANT
→
Open gate
Reloads the automatic closing
→
time if the automatic reclosing is
enabled, otherwise it closes.
During closing
OPEN
→
Summary of Contents for AS05800