23
Mounting
Check all mounting elements (consoles, torque brackets, screws, retaining rings etc.) for
tightness and impeccable condition.
Electric wiring
Check connection cables and cables for damage or pinches. Check screw connections for
correct seating and electrical contact.
Emergency manual operation
Function to be checked in a de-energised state. Carry out functional test only between final
limit positions.
Limit switches
Check the final limit positions by opening and closing the door completely. The safety zone
must not be reached.
Brake
Warning – Injury or danger to life possible!
Carry out brake test. Overrun depends on the door and its equipment. The
manufacturer's specifications must be observed.
Warning – Injury or danger to life possible!
Service life of the brake - replacement of the entire brake with motor in the case
of:
Operation with mains supply: after 750,000 door cycles
Operation with frequency inverter: after 1,500,000 door cycles