8
5
Technical data of the terminal box
Type
Ex e 8146/1041
Manufacturer
Stahl
Explosion protection
II 2G Ex e II T6
II 2D Ex tD A21 IP 66 T80°C
Certificate of verification
PTB 01 ATEX 1016
Supply voltage
250 max. 1100
V
Terminal cross-section
2.5
mm
2
Temperature range
T6: -20 / +40
T5: -20 / +55
°C
Protection class
IP 66
6
Technical data of limit switch / emergency manual operation switch
Type
07-2511-113061G
Manufacturer
Bartec
Explosion protection
II 2G Ex d IIC T6
II 2D Ex tD A21 IP 66 T80°C
Certificate of verification
EPS 14 ATEX 1766 X
Supply voltage
400
V
Temperature range
-20 / +40
°C
Protection class
IP 66
Attention – Damage to components!
The maximum allowable current applied to the limit switches is
2A 400V for AC-15 and 0.15 250V for DC-13.