Weld334m - User’s manual
F353-ADC Analogue Card
28
6.2
P2 . Description of the signals for the Solenoid valve and the TFE
The two green LED indicators are for the proportional solenoid valve and their function is
the following:
ENSERV
: = illuminated when the relevant output on P2 is active
STSERV
: = illuminated when the signal is present on the input.
15-way, Sub-d socket connector
Pin
Signal
Description
1
TFEsch
Screening of analogue voltage input
2
TFE-
Analogue voltage input
3
VServ-
0V voltage output for solenoid valve
4
IServ+
4-20mA current output for solenoid valve
5
Res2
Reserved
6
STSERV
Servovalve status input
7
0V
Solenoid valve power supply
8
24SV
Solenoid valve power supply
9
TFE+
Analogue voltage input
10
VServ+
0-10V voltage output for solenoid valve
11
Schield
Screening for ISERV or VSERV signal
12
IServ-
0V current output for solenoid valve
14
Res1
Reserved
15
ENSERV
Solenoid valve Enable Output
P2 . Functional description of signals
Pin
Signal
Function
1,2,9
TFE
Analogue voltage acquisition channel.
This input can be used for receiving the indication of the electrodes force
through a dedicated transducer.
4,12
ISERV
Current output. Operating range from 4 to 20 mA.
Signal for piloting a current type solenoid valve.
The valve adjusts pressure on the electrodes as a function of this signal, 20mA
correspond to 100% of the pressure value which has been calibrated on the
proportional valve.
Load resistor:470
Ω
(range: from 200 to 600
Ω)
3,10
VSERV
Voltage output. Operating range from 0 to 10V.
Signal for piloting a voltage type solenoid valve.
The valve adjusts pressure on the electrodes as a function of this signal, 10V
correspond to 100% of the pressure value calibrated on the proportional valve.
The output is protected against overcurrent and short circuit. In case of tripping
of the protective device, outgoing voltage falls to 0 Volt.
Typical resistive load: 10K
Ω
6
STSERV
Input. Electrodes pressure OK.
The logic condition 0V or 24V can be defined in the Setup stage.
Before welding, the control device waits for this signal produced by the solenoid
valve: if the logic condition is TRUE (24V), the control device gives the welding
pulse, if it is FALSE (0V), the welding sequence stays idle with the electrodes
closed.
7
0V
0V solenoid valve power supply.
8
24SV
Solenoid valve power supply
Power supply to the solenoid valve is monitored with a voltage value: if it falls
below 22.5V (5% of 24V), the ENSERV enable signal of the solenoid valve is not
activated.
F353-ADC
STSERV
ENSERV
P
2
S
E
R
V
O
V
A
L
V
E
Summary of Contents for Weld334m
Page 1: ...USER S MANUAL Weld334m HC HCM HIC HIM Ed 5 December 2004 Doc 39000326...
Page 6: ...Weld334m User s manual VI WHITE PAGE...
Page 14: ...Weld334m User s manual 8 WHITE PAGE...
Page 28: ...Weld334m User s manual 22 WHITE PAGE...
Page 30: ...Weld334m User s manual F351 BUS Interconnection card 24 WHITE PAGE...
Page 36: ...Weld334m User s manual F353 ADC Analogue Card 30 WHITE PAGE...
Page 40: ...Weld334m User s manual F364 SEV and F385 SEV Proportional Servovalve Modules 34 WHITE PAGE...
Page 42: ...Weld334m User s manual F359 MCP Memory Card and Printer 36 WHITE PAGE...
Page 54: ...Weld334m User s manual F356 IOE I O Expansion Card 48 WHITE PAGE...
Page 58: ...Weld334m User s manual F376 OPC Field Bus InterBus S Card 52 Card layout...
Page 61: ...Weld334m User s manual F386 Ethernet 100Base T and CANbus module 55 Card layout...
Page 62: ...Weld334m User s manual F386 Ethernet 100Base T and CANbus module 56 WHITE PAGE...
Page 64: ...Weld334m User s manual F383 COM RS422 Serial communication card 58 Card layout...
Page 73: ...Weld334m User s manual 67 APPENDIX...
Page 74: ...Weld334m User s manual 68...
Page 90: ...Weld334m User s manual 84 WHITE PAGE...
Page 92: ......
Page 93: ......
Page 94: ......