TSA 160 NT and variants
31
Electrical installation and device settings
7
Electrical installation and device settings
For electrical installation and device setting:
See wiring diagram
7.1 Mains connection
DANGER!
Risk of fatal injury due to electric shock!
X
The electrical system (230 V) may only be connected by a qualified electrician.
X
Observe the VDE regulations.
X
Before working on the electrical system, always disconnect the system from the mains.
X
Turn off the main switch provided on site and secure against accidental switching on.
CAUTION!
Damage due to incorrect supply voltage!
X
Before connecting the power cable, ensure that the specifications on the identification plate match the supply
voltage and that the fuse has been removed.
X
Pull off the side panel (3) by undoing the cylinder
head screws (4).
X
Lay the power cable and supply cable of the
control devices as shown in the cable plan and
connect as shown in the wiring diagram.
à
Surface mounting: Break out the required
recesses (2) of the side panel.
à
Concealed mounting: Cable through the recess
(1) in the base plate.
1 2 3
4
7.2 Settings
7.2.1 Limit stop
Factory setting: 90° door opening angle.
X
Open the door manually up to the required
opening angle or buffer and jam (wedge).
X
Set the blue cam plate (1) so that the limit switch
is activated in the open position of the door.
X
Lightly tighten the countersunk screw (2) on the
end face.
In the case of 2-leaf systems the blue cam plate (1) on the active leaf drive and on the passive leaf drive have to be
adjusted.