42
GEZE SecuLogic emergency exit system
1
24V
PA1
PA1
GND
24V
PA2
2
51
50
21
22
2
1
PA2
PE3
PE2
PE1
24V
24V
closed
locked
Locking
Locking device -
53
15
14
9
52
2
2
5
6
BU
GN
GY/PK
RD/BU
Door handle
contact (NO)
Cylinder
contact (NO)
BK
RD
Magnet -
TST 32x
X6
IQ lock EM
TST 32x
X4
1
If the IQ lock EM is to be engaged for the duration of unlocking:
Output PA1 to
BA.
Set the parameter for the
drive
and the type of contact to
normally open contact
.
In addition, connect output PA1 with the magnetic coil.
7.5.3 Motor lock IQ lock EL with MST 210
Heed the supplementary sheet for the motor lock IQ lock EL.
Set the parameter for input PE1 to:
à
Short-time unlocking
(factory setting): Operating the lock cylinder triggers short-time unlocking.
or
à
Cylinder contact
: The door control unit is controlled by the lock cylinder of the IQ lock EL:
in the state
Operating
lock cylinder
locked
unlocked
Alarm
less than 3 s
Short-time unlocking
-
-
3 s to 9 s
unlock
lock
acknowledge
longer than 9 s
Service mode
Service mode
Service mode
Set the parameter for input PE3 to
Door handle
. Pressing the door handle with the door control unit locked trig-
gers a pre-alarm.
Set the parameter for output PA2 to
TOE fail-secure
and the type of contact to
Normally open contact
.