23
GEZE SecuLogic emergency exit system
6.3.1 Fasten the impact cover to the support ring
If necessary, the impact cover can be screwed to the support ring:
1
2
1
X
Remove the inner part of the impact cover. To do this, press the inner part together at the two notches (1) and
pull it out (2).
X
Screw the lower part of the impact cover to the support ring. There are two holes provided on the support ring and
on the lower part of the impact cover (behind the film) for this purpose. Use self-tapping screw 2.2 mm x 9.5 mm.
X
Fit the inner part of the impact cover.
6.3.2 Fastening the key switch
If necessary, the cover (1) of the key switch SCT 320 can be screwed to the support ring:
1
X
There are two recesses on the back of the cover (1). Drill through the cover at these two spots (Ø 2.5mm)
X
Set the cover (1) in place and screw from the from (recommendation: 2.2 x 13 mm self-tapping screws).
The holes in the cover have to be countersunk accordingly for this.