13
GEZE SecuLogic emergency exit system
5.2.8 Door controller TST 32x
5.2.8.1 Variants
Door controller TST 320, door controller with GEZE bus, mat. no. 128958
Door controller TST 321, door controller with GEZE bus and delayed emergency button, mat. no. 128960
Door controller TST 322, door controller with GEZE bus, without emergency push button, mat. no. 128959
5.2.8.2 Terminal assignment
Plug-in and screw terminals, max. cable cross-section: 1 mm²
Terminal panel
Terminal
Function
X2 - BK
2
24V
12
lock, short-time unlocking, acknowledge
11
unlock, acknowledge
X3 - RD
1
GND
3
24VDC (supply)
46
GEZE bus (CAN-H)
45
GEZE bus (CAN-L)
42
RS485-A
41
RS485-B
X4 – BU
2
24V
22
COM
PA1
max. 1 A, 30 VDC
21
NO
1
GND
2
24V
51
COM
PA2
max. 1 A, 30 VDC
50
NO
X5 – GN
2
24V
1
GND
7
indirect disconnection
8
X6 – OG
53
PE3
52
PE2
9
PE1
2
24V
2
24V
15
closed
14
locked
6
Locking– (GND)
5
(24V)