Production test and commissioning
6
Production test and commissioning
6.1 Connecting the drive
WARNING
Risk of fatal injury due to electric shock!
X
The electrical system (230 V) may only be connected and disconnected by a professional electrician or specialist
electrical technician.
X
Carry out mains connection and earth conductor test in accordance with VDE 0100 Part 600.
X
Remove the sheath of the mains cable (4) on a max. of 40 mm.
2
3
9 mm
PE
9 mm
max. 30 mm
10 mm
4
X
Strip the mains cable (4).
à
Sheath removal length 40 mm
à
Stripping length 9 mm
à
PE line lead 10 mm
X
Connect the drive to the 230 V mains network.
X
Switch on the main switch (2) on the transformer (3).
X
Insert the rechargeable battery connector (1) at the control unit.
1
X
Carry out the production test as described in the wiring diagram “Automatic sliding doors DCU1-NT/DCU1-2M-NT”.