www.geyserwise.co.za
10
Geyserwise ECO MPPT Technical Specifications
•
Maximum input voltage 46—138 VOC, 36—108 VMP
•
Peak efficiency 98%
•
Maximum output amps 25A
•
Ambient temperature Up to 70°C but de-rated at 1A per degree at temperatures above 50°C. Do not
expose to direct sunlight.
•
Environmental IP43
•
Indications 2 LED’s
•
Heating (input command from thermostat)
•
Tracking (PV active)
•
Power (device turned on)
•
Inputs/Outputs - potential free
Geyserwise TSE1 Controller Technical specification
•
Operating voltage 230VAC / 50HZ.
•
Main relay contact rating 30A (max 4kW element).
•
Operating voltage range 160V - 250V AC.
•
Recommended ambient temperatures: -7 - 50°C; max 75°C
•
Temperature display range 0 - 99°C.
•
Temperature setting ranges 30 - 65°C (AC Settings)
•
Temperature setting ranges 50 - 75°C (DC Settings)
•
Change over switch to heat secondary geyser from PV array
•
Heat failure - when increase at a rate of 4°C or less per hour, AC only.
•
Mechanical thermal cut-out 90°C (300 manual resets) on AC only.
•
Mechanical thermal cut-out 75°C on DC thermostat, 10 000 cycles.
•
Thermal cut-out - Isolate live.
•
Dry heat detection - empty cylinder.
•
Temperature tolerance ± 5°C and manufacturing drift is less than 6°C.
•
Temperature differential setting 1°C.
•
Temperature probe failure detection for the tank.
•
Temperature probe range for geyser is -30 to +130°C.
•
Control box insulated - Class 1.
•
Operating life - 50 000 cycles.
•
SANS 181 compliant.
PV System Installers Guide
__________________________
Installation
Summary of Contents for 100L geyser
Page 39: ...www geyserwise co za 37 PV System Installers Guide ___________________________________ NOTES...
Page 40: ...www geyserwise co za 38 PV System Installers Guide ___________________________________ NOTES...
Page 41: ...www geyserwise co za 39 PV System Installers Guide ___________________________________ NOTES...