Take the insert off the stem.
You do not have to remove the stud bolts
from the body.
In the following drawings the stud bolts are
not shown for reasons of clarity.
Attaching pressure balance element
Put the sleeve (50) of the pressure balance
device into the insert (6).
Attention!
Malfunctions may occur if the packing
rings are damaged.
Before installation discard and replace
any damaged packing rings.
Make sure that the packing rings are
correctly positioned and not damaged
or skewed when fitted.
Put the packing rings (51) into the insert.