Illustration 9: Determination of the start force
Below, the Evaluating Window can be generated. The factory setting is a window size of
±10% of the average values of the break forces and break strokes. There for press the key
.
The size of the Evaluating Window is application-specific and defined on the basis of
the sample rivetings and, if necessary, further tests.
The size of the Evaluating Window is determined by entering the absolute values for the limits
of the window, or by entering deviations from average values in percent.
Furthermore, the window can be brought into application-specific size by dragging the
boundaries, or moving by mouse. Illustration 10 shows the generation of the Evaluating
Window