Electrical Connections
Installation Guidelines
•
Circuit requirement: single-phase AC power supply (220V - 240V ~ 50/60 Hz).
•
Drawings below shows the lid of the connection box.
•
Before connecting the appliance, make sure that the supply voltage marked on the rating plate
corresponds with your mains supply voltage.
•
Power cord should be tightened safely.
The installation must be carried out by a suitably qualified person, in accordance with the current
version of the following.
•
UK Regulations and Safety Standards or their European Norm Replacements.
•
Building Regulations (issued by the Department of the Environment).
•
Building Standards (issued by the Scottish Development Department).
•
IEE Wiring Regulations.
•
Electricity At Work Regulations.
Before connecting the appliance, make sure that the supply voltage marked on the rating plate
corresponds with your mains supply voltage.
WARNING: THIS APPLIANCE MUST BE EARTHED.
This appliance should be wired into a 10A double pole switched fused spur outlet, having 3 mm
contact separation and placed in an easily accessible position adjacent to the appliance. The spur
outlet must still be accessible even when your oven is located in its housing.
To connect the oven power cord, remove the cover on the terminal
block, in order to gain access to the contacts inside. Make the
connection, securing the cord in place with the cable clamp provided
and then immediately close the terminal block cover again.
•
Connect the wires as indicated in the image above, using the brass links provided where
necessary.
•
The earthing (yellow/green) conductor must always be 10 mm longer than the line conductors.
•
Care must be taken to ensure that the temperature of the mains supply cable does not exceed
50°C.
•
If the mains supply cable is damaged, then it must be replaced by an appropriate replacement
which can be obtained from the manufacturer.
Caution!
The power supply should have a safety switch to cut off the power in time in case
of an emergency. Before connecting the power cord, be sure to read the label
and connection diagrams carefully.
Electrical Connections
PE
N
L
N
L
Caution! In the event of any connection the safety
wire must be connected to the PE terminal
CONNECTION DIAGRAM
Caution! Voltage of heating elements 220V~240V
For 220V-240V earthed one
phase connect on: Brown wire
connect to L and blue wire
connect to N, safety wire
(Yellowgreen) connect to
LIVE
BROWN
BLUE
YELLOW/GREEN
MAINS
POWER
SUPPLY
POWER CORD
L
EARTH
NEUTRAL
N
E