Communications Setup
There are two ways of communicating with the Infinity plotter: Serially
(Infinity 45 or 85) or by the network (Infinity 85). The Infinity needs to be
set up to use either one of those communication methods.
Serial Use Setup – Infinity 45 and Infinity 85
1. Open Gerber Devices by selecting Start/Settings/Control
Panel/Gerber Devices.
2. Click on the
Plotter
tab.
3. Select the appropriate Comm Port in the output field.
4. Select
19200 bps
as the baud rate.
5. Select
Gerber Infinity 45
or
Gerber Infinity 85
, as
appropriate.
6. Click
OK
.
7. Verify that plotter icon is present in system tray at bottom
right corner of screen.
Network Use Setup - Infinity 85
Plotter Setup
Make these selections using the Infinity plotter control panel.
1. Set the Comm Interface for network operation as follows:
a) Make sure the plotter is offline.
b) Push
the
Menu
button (4 times) until Select
Comm Interface is displayed.
c) Push
Select
.
d) Push
Menu
until
Select Network
is displayed.
e) Push
Select
. The asterisk should appear in the
display to confirm the choice as default setting.
f) Push
Online
(2 times) to reset and to put the
plotter offline for baud rate selection in step 2.