4. Operating
Optima 310
All Genvex combined ventilation units and domestic hot
water pumps types Combi for houses and are delivered
with Optima 310 control systems, which have default
settings such that the unit can be put into operation.
The default setting is only a basic setting that should be
changed to the operating wishes and requirements of
the house in question and will thereby achieve optimal
utilisation and operation of the device. After the device
has been started, the control panel will be in stand-by and
will display one of the screen savers (can be changed in
the main menu under the item ‘display’). Pass your hand
over the control panel to bring up the symbols on the
screen that show the daily operating options.
4.1 Operating and changing data in
the operating menu
The display normally shows the screen with symbols for
daily operations, where the following buttons can be seen
in connection with daily operation.
Speed (1)
Use this function to set the fan speed to levels 0-1-2-3-4.
The button beside the speed symbol changes between
the 4 speeds. The installation can also be stopped by
holding down the button for 3-4 seconds.
Extended operation (2)
Use this function to set the timer to forced operation
from 0 to 9 hours Use the button next to the symbol for
extended operation to change from 0 to 9 hours. If the
timer is set to 0, speeds 3 and 4 will run until the speed is
changed manually. If the timer is set for between 1 and 9
hours, speeds 3 and 4 will automatically be linked back to
speed 2 after the number of hours the symbol was set at.
Electric catridge (3)
Use this function to turn on or off the supplementary after-
heat.
Use the button beside the after-heat symbol to change
between ON or OFF. If the symbol is set at ON and the
device is equipped with an after-heat surface, the after-
heat will commence as required. If, on the other hand, the
symbol is set to OFF, the after-heat will not commence,
even if it is required.
Temperature (7)
Use this function to set the room temperature.
Use the button next to the temperature symbol to set
the required temperature from 10-65°C. The current
temperature will be displayed at the centre of the screen.
Information (6)
Use this function to get a good overview of the device’s
current operating condition, e.g. temperature, fan setting,
relay status/functions, alarm, timer etc.
Use the button beside the info symbol to read the
installation’s operating condition (more information can be
found in the main menu section under the info operation
item).
Filter (5)
Use this function to un-set the filter alarm. The button
beside the filter symbol un-sets the alarm for filter
change. To un-set the filter alarm, change the filters
hold down the button with the filter symbol until the
exclamation mark in the symbol disappears.
Main menu (4)
Use this function to enter the main menu and access the
sub-items date, calendar, user menu, display, information
menu and service menu.
Press help to see a guide for the item that is marked.
Press the exit to return to the previous display screen.
The setting will not be saved when you press here. Use
the arrow buttons to navigate in the menus. The two
arrow buttons will change to plus and minus when you
change the setting.
Use the Enter button to proceed through the menus. If a
menu item has been changed, finish by pressing Enter
and the change will be saved.