Gentherm Global Power Technologies 3-5
P-5050
62553 Rev.8
3.6 Fuel Consumption
The P-5050 is certified to operate on commercial propane and natural gas.
The fuel consumption of the P-5050 at rated power is listed in the table below for various
fuels.
Fuel Consumption
at Rated Power
Propane
Natural Gas
lb/hr*
0.3
-
gal/hr*
0.08
-
kg/hr*
0.15
-
L/hr*
0.29
-
ft
3
/hr**
2.88
7.2
m
3
/hr**
0.081
0.205
* At 20ºC (68ºF)
** At atmospheric pressure and 20ºC (68ºF), assuming an energy content of 37.3 MJ/m
3
or
1000 BTU/ft
3
Figure 2
Data Plate
Summary of Contents for P-5050
Page 4: ......
Page 8: ......
Page 44: ...Gentherm Global Power Technologies 5 12 P 5050 62553 rev 8 ...
Page 46: ...Gentherm Global Power Technologies 6 2 P 5050 62553 rev 8 ...
Page 60: ...Gentherm Global Power Technologies 8 10 P 5050 62553 rev 8 ...
Page 98: ...Gentherm Global Power Technologies 14 4 P 5050 62553 rev 8 ...