56
•
Operational Reference
Genie Nano-CL Series™
Counter Value
counterValue
Read the current value of the selected counter.
1.00
Expert
DFNC
Counter Value At Reset
counterValueAtReset
Stores the counter value of the selected counter when
it was reset by a trigger or by an explicit Counter
Reset command.
1.00
Expert
DFNC
Counter Reset
counterReset
Resets the selected counter to zero. The counter
starts immediately after the reset. To temporarily
disable the counter, set the Counter Event Source
feature to Off.
1.00
Expert
DFNC
Timer Selector
timerSelector
Selects which timer to configure.
1.00
Expert
DFNC
Timer 1
Timer1 Timer 1 selected
Timer Mode
timerMode
Select the Timer mode. The selected Timer is Active
or Disabled. When Disabled, the Timer can be
configured.
1.00
Expert
DFNC
Off
Off The selected Timer is Disabled.
Active
Active The selected Timer is Enabled.
Timer Status
timerStatus
Returns the current state of the timer.
1.00
Expert
DFNC
Timer Idle
TimerIdle The timer is idle. The CounterStartSource feature is
set to off.
Timer Trigger Wait
TimerTriggerWait The timer is waiting for a start trigger.
Timer Active
TimerActive The timer is counting for the specified duration.
Timer Completed
TimerCompleted The timer reached the TimerDuration count.
Timer Start Source
timerStartSource
Select the trigger source to start the timer. The
provides details and timing diagrams
for the supported events.
1.00
Expert
DFNC
TimerReset Cmd
Off Starts with the reception of the TimerReset
Icommand.
Exposure Start
ExposureStart Start Timer on Exposure Start event.
Exposure End
ExposureEnd Start Timer on Exposure End event.
Readout Start
ReadoutEnd Start Timer on Readout Start event.
Readout End
ReadoutStart Start Timer on Readout End event.
Frame Start
FrameStart Start Timer on Frame Start event.
Frame Trigger
ValidFrameTrigger Start Timer on Frame Trigger event.
CC1
CC1 Start Timer on a transition of I/O CC1 event.
Counter 1 End
Counter1End Start Timer on Counter 1 End event.
Timer Line Activation
timerStartLineActivation
Select the trigger activation mode which starts the
timer.
1.00
Expert
DFNC
Rising Edge
RisingEdge Starts counter on rising edge of the selected signal.
Falling Edge
FallingEdge Starts counter on falling edge of the selected signal.
Any Edge
AnyEdge Starts counter on the falling or rising edge of the
selected signal.
Timer Duration
timerDuration
Sets the duration (in microseconds) of the timer
pulse.
1.00
Expert
DFNC
Timer Value
timerValue
Reads the current value (in microseconds) of the
selected timer.
1.00
Expert
DFNC
Timer Reset
timerReset
Resets the timer to 0 while timerStatus=TimerActive.
Timer then waits for the next timerStartSource event.
1.00
Expert
DFNC
Summary of Contents for Nano-CL C2450
Page 94: ...92 Technical Specifications Genie Nano CL Series EC FCC Declarations of Conformity...
Page 104: ...102 Additional Reference Information Genie Nano CL Series Cable Assembly G3 AIOC BLUNT1M...
Page 105: ...Genie Nano CL Series Additional Reference Information 103 Cable Assembly G3 AIOC BLUNT2M...
Page 106: ...104 Additional Reference Information Genie Nano CL Series...
Page 107: ...Genie Nano CL Series Additional Reference Information 105 Cable Assembly G3 AIOC BRKOUT2M...
Page 108: ...106 Additional Reference Information Genie Nano CL Series...