Section 3 • Scheduled Maintenance Procedures
REV B
November 2005
3 - 8
GR-12 • GR-15 • GR-20
Part No. 84700
Checklist B Procedures
B-1
Inspect the Batteries
Proper battery condition is essential to good
machine performance and operational safety.
Improper fluid levels or damaged cables and
connections can result in component damage and
hazardous conditions.
Electrocution hazard. Contact with
electrically charged circuits could
result in death or serious injury.
Remove all rings, watches and
other jewelry.
Bodily injury hazard. Batteries
contain acid. Avoid spilling or
contacting battery acid. Neutralize
battery acid spills with baking soda
and water.
Perform this procedure after fully
charging the batteries.
For a more accurate determination
of battery condition, fully charge
the batteries and allow the
batteries to rest 24 hours before
performing this procedure to allow
the battery cells to equalize.
1 Put on protective clothing and eye wear.
2 GR-12: Raise the platform
approximately 3 feet / 1 m.
GR-15 and GR-20: Raise the platform
approximately 5 feet / 1.5 m.
a
batteries B5
b
275A fuse F6
c
quick disconnect QD1
d
battery charger U9
3 Open the battery cover. Rest the cover against
the chassis.
4 Lower the platform until the mast just contacts
the battery cover.
Crushing hazard. Keep hands
clear of the battery cover when
lowering the platform.
5 Be sure that the battery cable connections are
free of corrosion.
6 Be sure that the battery retaining fasteners and
cable connections are tight.
-
+
-
+
-
+
-
+
275A Fuse
F6
-
+
QD1
a
b
c
Battery Charger
U9
RD
BK
d