Section 4 • Repair Procedures
REV B
November 2005
4 - 8
GR-12 • GR-15 • GR-20
Part No. 84700
1-3
Software Configuration
The Electronic Control Module (ECM) contains
programming for all configurations of the Genie
Runabout. The machine can be adjusted to a
different configuration using the buttons at the
platform controls.
How to Determine the
Software Configuration
1 Remove the platform controls from the platform.
2 Turn the key switch to platform control and pull
out the red Emergency Stop button to the on
position at both the ground and platform
controls.
Result: The diagnostic display at the platform
controls will show the battery condition. See
1-3, How to Determine the Battery Voltage.
3 Press the lift function select button.
4 Slowly move the joystick in the direction
indicated by the blue arrow.
Result: The machine configuration code will
appear in the diagnostic display.
5 Push in the red Emergency Stop button to the
off position at both the ground and platform
controls and turn the key switch to the off
position.
PLATFORM CONTROLS
a
b
d
e
c
f
a
joystick controller JC1 with thumb
steering rocker SW6
b
lift function select button BN9
c
diagnostic display
d
red Emergency Stop button P2
e
drive function select button BN8
f
blue arrow