Sec-3.13
Sensing Edges, Hardwired with Expansion Board
1. Mount junction box to wall one half the door height plus 12 inches from floor.
2. Install hard-wiring from operator and coil cord to junction box and secure with conduit clamps.
3. Connect hard-wiring from operator to coil cord with wire nuts and install junction box cover plate.
4. Connect coil cord to sensing edge with wire nuts.
5. Install hard-wires to TCM or ESM in operator. (See instructions included with expansion boards for
detailed installation and wiring)
Actuating the operator by using constant contact on the CLOSE button will override non-functioning
external reversing devices, including sensing edges.
WARNING
!
AVERTISSEMENT
!
L’activation de l’operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs
d’inversions externes, y compris les systèmes de détection des bords.
1/2 Door Height
+ 12in.
TCM or ESM Board
with ASO or MillerEdge
DC/T3 monitored edge
GND
MON
EDGE
Junction
Box
NOTE:
DO NOT use take up
reels with Monitored Edge
systems
Section 3: Wiring
Miller Edge ‘DC’ Series & ASO Sentir GF Series Monitored
Sensing Edge Installation with Timer Control Module (TCM)
or Edge Sensing Module (ESM)