Condition
Code
DISPLAY
Condition Code Description
0C
IDLE > DOWN LIMIT
STANDING BY AT DOWN LIMIT (NOTE: THIS MESSAGE IS DISPLAYED IF BOTH LIMITS ARE ACTIVE)
0D
IDLE > UP LIMIT
STANDING BY AT UP LIMIT
0E
IDLE > MID STOP
STANDING BY AT MID-STOP LIMIT
0F
IDLE > NO LIMIT
STANDING BY BETWEEN LIMITS
10
OPENING > OPEN BTN OPENING FROM OPEN BUTTON
11
OPENING > ONE BTN
OPENING FROM 1 BUTTON
12
OPENING > RADIO
OPENING FROM RADIO
13
OPENING > AUX OPEN
OPENING FROM AUXILIARY OPEN INPUT
14
OPENING > OPEN KEY
OPENING FROM KEYPAD OPEN KEY
20
CLOSING > CLOSE PB
CLOSING FROM CLOSE BUTTON
21
CLOSING > ONE BTN
CLOSING FROM 1 BUTTON
22
CLOSING > RADIO
CLOSING FROM RADIO
24
CLOSING > CLOSE KP
CLOSING FROM KEYPAD CLOSE KEY
2A
CLOSING > TCM CLS
CLOSING FROM TIMER CLOSE MODULE
2B
CLOSING > FDM CLS
CLOSING FROM FORE DOOR MODULE
30
HALT > WALL BUTTON GDO STOPPED BECAUSE STOP OR OPEN BUTTON WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
31
HALT > ONE BUTTON
GDO STOPPED BECAUSE 1 BUTTON WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
32
HALT > RADIO
GDO STOPPED BECAUSE RADIO INPUT WAS ACTIVATED, STARTING A REVERSAL
33
HALT > AUX. OPEN
GDO STOPPED BECAUSE AUXILIARY OPEN INPUT WAS ACTIVATED, STARTING A REVERSAL
34
HALT > KEYPAD KEY
GDO STOPPED BECAUSE KEYPAD STOP OR OPEN KEY WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
35
HALT > N-O SAFETY
GDO STOPPED BECAUSE N-O REVERSING INPUT WAS ACTIVATED, STARTING A REVERSAL
36
HALT > ODC STB
GDO STOPPED BECAUSE THE ODC STB WAS BLOCKED, STARTING A REVERSAL
37
HALT > N-C SAFETY
GDO STOPPED BECAUSE N-C REVERSING INPUT WAS ACTIVATED, STARTING A REVERSAL
38
HALT > MON. EDGE
GDO STOPPED BECAUSE MONITORED EDGE SENSOR INPUT WAS ACTIVATED, STARTING A REVERSAL
39
HALT > DOOR FORCE
GDO STOPPED BECAUSE THE FORCE REQUIRED TO OPERATE THE DOOR WAS TOO HIGH, POSSIBLY STARTING A REVERSAL
3A
HALT > LOSS OF C/C
GDO STOPPED BECAUSE CONSTANT CONTACT ON CONTROL REMOVED BEFORE REACHING A LIMIT, POSSIBLY STARTING A REVERSAL
3B
HALT > SHUTDOWN
GDO STOPPED BECAUSE THE GDO DETECTED A FAULT SUCH AS AN OPEN INTERLOCK, OVERHEATED MOTOR, ETC.
3C
HALT > DOWN LIMIT
GDO STOPPED BECAUSE IT REACHED THE DOWN LIMIT
3D
HALT > UP LIMIT
GDO STOPPED BECAUSE IT REACHED THE UP LIMIT
3E
HALT > MID STOP
GDO STOPPED BECAUSE IT REACHED THE MID-STOP LIMIT
3F
HALT > MODULE FAIL
GDO STOPPED BECAUSE AN EXPANSION MODULE WAS NOT WORKING PROPERLY
40
REV > OPEN BUTTON
GDO REVERSED BECAUSE THE OPEN BUTTON WAS ACTIVATED
41
REV > ONE BUTTON
GDO REVERSED BECAUSE THE 1 BUTTON WAS ACTIVATED
42
REV > RADIO
GDO REVERSED BECAUSE THE RADIO INPUT WAS ACTIVATED
43
REV > AUX OPEN
GDO REVERSED BECAUSE THE AUXILIARY OPEN INPUT WAS ACTIVATED
44
REV > OPEN KEY
GDO REVERSED BECAUSE THE KEYPAD OPEN KEY WAS ACTIVATED
45
REV > N-O SAFETY
GDO REVERSED BECAUSE THE N-O REVERSING INPUT WAS ACTIVATED
10.11
Section 10: Appendix C
Run Code Displays
www.geniecompany.com
01-14