Sensing Edge Installation (continued)
shows the connection of OPAKMMWE.S MEL Miller Edge Monitored Wireless Sensing Edge.
Figure 12
Figure 12
CONTROL SIGNAL TERMINAL STRIP
ODC
STB
ODC
STB
SENSING EDGE
WIRELESS
EDGE RECEIVER
WIRELESS EDGE
TRANSMITTER
EXT RADIO
CONNECTOR
PWR
20-40 VDC @ 250mA
MAX. CURRENT
RADIO
NOM
+24VDC
GND
RELAY
BLUE
YELLOW
ORANGE
BLK
RED
WIRE NUT
WHT
GRN
7) Operate the door to make certain cord is free to travel and does not become
snared during door opening or closing.
•
Check sensing edge for proper operation.
8)
While the door is closing actuate the sensing edge to verify the door reverses to open limit.
WARNING:
To obtain proper operation of the MEL edge sensor, each transmitter/receiver set
must be set to a unique address. Follow instructions provided with the Miller Edge MEL kit to set the address.
AVERTISSEMENT:
Pour obtenir un fonctionnement correct du capteur de
bord MEL, réglez chaque ensemble émetteur/récepteur sur une adresse unique. Suivez les instructions fournies