background image

23

TROUBLESHOOTING GUIDE (CONTINUED)

FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM

Check lock switch on wall console.

Check power source.

Plug a lamp into outlet used for power 
head If lamp works, power source is OK.

If not, check fuse or circuit breaker.

Power is OK.

Check connections at power head 

terminals.

Check connections at wall control.

Check wires to ensure they are not cut. 
Staples can cut insulation and short wires. If 
wire is cut, replace it.

Was a remote control lost or stolen? 
Erase all remote control codes from 
receiver memory and reprogram 
(See section 

).

Button stuck on wall control.

Check CLOSE limit switch setting 
(See section  ).

Wires shorted.

Check CONTACT REVERSE
(See section  ).

Check “STB” system for beam obstruction 
or misalignment of lenses (See section  ).

Check “STB” diagnostic code.

Check “CLOSE FORCE” adjustment 
(See section  ).

Check OPEN limit switch for short and 
proper wiring.

Check “OPEN FORCE” adjustment
(See section  ).

Check door condition and door spring.

Check “STB” system (See self-diagnostic 
“STB” Troubleshooting Chart).

Check CLOSE limit switch for short and 
proper wiring.

Check “CLOSE FORCE” adjustment 
(See section  ).

Disconnect and reconnect wires on wall control
(See section  ).

Check wiring.

Incompatible wall control.

4

6

6

6

3

6

6

7

Use wall control supplied with operator. Any other wall control can cause
the operator to operate unexpectedly and light not to work.

CAUTION

Door starts down,
then stops before
it’s closed

.

Be sure door, operator, and springs are in 
good repair, properly lubricated and balanced 
(See maintenance section).

Check “OPEN” limit switch setting       
(See section 

).

Check “OPEN FORCE” adjustment       
(See section 

).

Make sure carriage is engaged to 
carriage slide.
– Place carriage lever in lock position.

Check force adjustment (See section 

).

Door operator will 

NOT

run more than    

30 seconds each way if door does 
not move.

Relocate remote control inside car.

Point remote control at garage door.

Replace battery (See section 

).

Reposition door operator antenna.

DO NOT

attempt to retune remote controls.

Program remote control code into      
receiver memory. (See section 

).

Replace remote control battery with good 
one. (See section 

).

Be sure all fasteners are tight.

Be sure door and operator is in good repair, 
properly lubricated and balanced (See 
monthly maintenance section).

If an operational problem exists, and operator
will not run closed. The operator can be forced
to close as follows (See section 

).

Disconnect the “STB” system from 
the operator.

Hold the wall control button down until door is
completely closed. 

Use self-diagnostic “STB” system Troubleshooting
information to maintain safe operation.

5

8

7

8

6

6

6

Door starts up,
but stops before
it’s completely
open

.

Door will only
run closed

.

Door operator
starts for 
no reason

.

Operator does 
not run from 
wall control

.

Door starts
down, then stops
and goes 
back up

.

Lights will not go
out

Door will only
run open

Remote control
has less than 
25 feet 
operating range

.

Operator runs,
but door does
not move

.

Safe-T-Beam

®

system
malfunction

Noisy operation

.

Operator works
from wall 
control, but 
not from 
remote control

.

If you have any questions, please do not hesitate to
contact customer service at:

1.800.354.3643 

Summary of Contents for Chain Glide

Page 1: ...close door SAVE THIS MANUAL FOR FUTURE REFERENCE NOTE Your Residential Operator comes with a Rail Assembly which is standard for up to a 7 foot 6 inch high door An extension kit for an 8 foot high do...

Page 2: ...rom obstruction and has a wood surface available for attaching the STB brackets The brackets may be attached to concrete if necessary but extra tools and special fasteners not supplied will be require...

Page 3: ...54 3643 OR GENIECOMPANY COM TYPICAL SUPPORT BRACKET EXTENSION SPRING OR TORSION SPRING SAFE T BEAM BRACES ADDED HEADER BRACKET MOUNTING BOARD TYPICAL 1 PIECE DOOR INSTALLATION 48 POWER CORD TO 120V GR...

Page 4: ...m inside garage Independent light control allows convenient manual control of the automatic lighting system NOTE Your garage door operator may not come with all above items included as standard equipm...

Page 5: ...35 33 31 32 37 FASTENERS Shown Full Size See Parts List for description Lag screw 1 4 x 2 22 Screw 8 32 x 1 39 Self drilling Screw 1 4 20 x 3 4 42 Nut 1 4 20 10 Cotter pin 25 Clevis pin 24 Wire clip...

Page 6: ...800 354 3643 OR GENIECOMPANY COM 2 3 PIECE RAIL HARDWARE EXPLODED VIEW 4 10 3 9 11 25 15 16 23 28 17 27 25 26 42 24 20 12 18 47 22 9 10 41 41 10 13 39 12 10 39 14 8 9 22 18 47 7 26 42 20 24 6 9 15 11...

Page 7: ...assembly 1F Capacitor by series model 1G Opto wheel not shown 1H Carriage slide 1J Chain POWER HEAD PARTS LIST pre assembled Garage doors are large heavy objects that move with the help of springs un...

Page 8: ...refer to the instruction sheet included with the optional rail extension at this point OPEN BLUE PARTS BAG 3 Attach rail clamps to rail Fig 1 3 Use pair of clamps at both joints Fasten each pair with...

Page 9: ...l to power head magnet Make sure that the carriage magnet is in place in the top of the carriage slide CAUTION 7 Attach emergency release cord knob and tag Tie overhand knot in 1 end of cord Tighten k...

Page 10: ...Fig 1 10 Turn set screws 39 into threaded holes just enough so screw stays in place Fig 1 10 Point arrow on top CLOSE limit switch toward door end of rail Place CLOSE limit switch Brown wire on rail...

Page 11: ...ntacts a 1 1 2 inch high object on the floor at the center of the doorway This is the size of a 2 x 4 board laid flat HEADER AND DOOR MOUNTING BRACKETS 1 Finding header bracket mounting location Close...

Page 12: ...WER THAN top set of rollers Fig 2 7 For 1 piece doors door bracket must be mounted at top edge of door 4 Mounting the door bracket Proper bracing should be verified at this point Align door bracket ce...

Page 13: ...door at highest point of travel b Be level or power head slightly below level Trackless doors a Rail must clear door at highest point of travel by 1 to 1 1 2 Securely tighten power head mounting bolt...

Page 14: ...or arms sectional doors 27 28 INSTALL DOOR ARMS 1 piece doors OPEN YELLOW PARTS BAG 1 Attach the arms Straight arm to door bracket using clevis pin 24 and cotter pin 25 Fig 2 12 Curved arm to carriage...

Page 15: ...r Determine which side of garage receives most direct sunlight Fig 3 4 Red LED should always be on sunny side whenever possible Fig 3 4 For multiple doors Preventing crossed signals is critical Place...

Page 16: ...the following Insure that no part of door or its hardware is in path between lenses of source and sensor Insure that tops of lenses are between 5 6 above the floor Fig 3 9 The brackets are flexible an...

Page 17: ...2 3 Mounting Fasten wall control to wall with 2 screws 33 Fig 5 3 Remove protective backing from entrapment warning label Fig 5 4 Stick label on wall near wall control NOTE Additional wall controls ar...

Page 18: ...ushing Connect permanent wiring to power head White to white black to black ground to green Use only UL recognized wire nuts Wires inside power head must be at least 6 in length Replace motor cover an...

Page 19: ...g rail to align front edge of switch with back edge of carriage Fig 7 4 Gently tighten set screw Manually close door Place emergency release lever in engaged position Press wall control button Carriag...

Page 20: ...erference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television r...

Page 21: ...replacement Use coin ball point pen or similar device Gently push straight in on battery cover lock tab as shown Fig 9 1 Flip open battery cover Remove old battery Make sure new battery is facing pro...

Page 22: ...l emergency release knob toward power head to place release lever in engaged position Operate door using remote Door will re attach itself to carriage assembly 3 Contact reverse Place a 2 x 4 board la...

Page 23: ...repair properly lubricated and balanced See maintenance section Check OPEN limit switch setting See section Check OPEN FORCE adjustment See section Make sure carriage is engaged to carriage slide Plac...

Page 24: ...ser diferentes a las reglamentaciones de los Estados Unidos y del Canad antes de usar los mismos Les metteurs sont conformes la r glementation am ricaine et canadienne compter de leur date de fabrica...

Page 25: ...Juego de extensi n deslizante Una extensi n de 18 pulgadas para aumentar la carrera de un abridor deslizable de cadena para acomodar una puerta de 8 pies 2 43 m N cessaire de rallonge du Chain Glide...

Page 26: ...lit Perfect Stop GPS 5BL Stop Perfecto 34964R 04 95 Butoir Perfect Stop Chain Glide Extension Kit LCGX 8 Juego de extensi n de cadena deslizable 00001085 34 95 N cessaire de prolongement du coulisseau...

Page 27: ...___________________________________________________________________________ Dealer Address _________________________________________________________________________ City ______________________________...

Reviews: