Genie Raptor Manual Ver. 3.1
14
Edition. GN-April-2013
DIP SW
ID
DIP SW
ID
DIP SW
ID
1011001
77
0010011
100
1101111
123
0111001
78
1010011
101
0011111
124
1111001
79
0110011
102
1011111
125
0000101
80
1110011
103
0111111
126
1000101
81
0001011
104
1111111
127
0100101
82
1001011
105
1100101
83
0101011
106
• RS485 Termination
If Raptor is using RS485 communication, please make sure the Bus is correctly installed and configured
to prevent malfunctions. The maximum allowed cable distance is 1200 metres. A Maximum of 32 units
can be connected to a cable section.
Any cable type which exceeds the specification of EIA RS485 can be used. The furthest device, by cable
length, should be terminated in accordance with the specification. Other devices should remain un-
terminated (see Figure 11 below).
• Keyboard Operation
Key Sequences and Joystick movements are executed to closely control the camera and program the
Telemetry Control system of Raptor II. Examples of these are PRESET and TOUR.
If a Keyboard cannot be used to access and change the camera parameters, most characteristics are
accessible through the camera’s OSD menu.
Note – Changing a Keyboard’s Software and/or Protocol can effect alterations to the camera’s
operability. The Raptor manufacturer absolves itself of responsibility for such modifications.